background image

G

EN

ER

A

L O

PE

RA

TIO

N

GENERAL OPERATION 

Carefully read the description of the charbroiler operation on the

specification sheet.

Do NOT use this appliance if it has been submerged in water.

Call a qualified technician to examine the appliance and to service

or replace any component which has been submerged. Burners

which have been allowed to become wet must be thoroughly dried

before use.

For initial startup, and any time the gas supply has been shut-off, it

may take several minutes to light the pilot while air in the piping and

manifolds is purged.

The burner control knobs must be turned by hand only. Never use

tools to turn the control knob. If the knob will not turn by hand, DO

NOT attempt to force or repair it. Contact your manfacturer for

repairs. Forced or improperly repaired valves pose the risk of fire and

or explosion.

Make sure burners, pilot burner and drip tray are properly installed

before attempting to operate.

LIGHTING THE PILOT FLAME

Before lighting the pilot light, smell all around the appliance area for

gas. Be sure to smell near floor level because some gas is heavier

than air and will settle to the floor.

For initial startup, and any time the gas supply has been shut-off, it

may take several minutes to light the pilot while air in the piping and

manifolds is purged.

The pilot light must be lighted by hand:

Remove grates. Turn all control knobs to the full OFF position.

Wait 5 minutes.

The pilot is located adjacent to the burner, and is accessible from

the top of the unit.

Be sure the gas shut-off valve is ON and the appliance has had

time for the air to be purged from the lines. Attempt to light the

pilot every 15 seconds after the gas valve is turned on.

Light the pilot with a long match or fireplace lighter.

DO NOT use a cigarette lighter.

Reinstall grates

SHUT DOWN INSTRUCTIONS

Turn all burner knobs to OFF.

Turn all pilots OFF.

Turn the main gas supply OFF.

WARNING:

FIRE HAZARD

IF YOU SMELL GAS:

DO NOT try to light any appliance.

DO NOT touch any electrical switch

DO NOT use any telephone in your

building.

In the event a gas odor is

detected, shut down the

unit at the main gas shutoff

valve and contact your

local gas supplier from a

neighboring location.

Follow the instructions

received from the gas

supplier immediately

and exactly.

Page 9

Summary of Contents for SCB48-HD

Page 1: ...re or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service and maintenance can cause property da...

Page 2: ...on the repair or replacement of any part found by Saturn to be warranted herein Saturn shall bear the normal labor charges for repair or replacement to the extent that such repair or replacement is pe...

Page 3: ...container for inspection Manufactuer cannot assume liability for damage or loss incurred in transit We will however at your request supply you with the necessary documents to support your claim INTRO...

Page 4: ...FEATURES AND OPERATING CONTROLS FEATURES OPERATING CONTROLS Page 3 Fig 1 Heavy Duty Gas Charbroiler Features Operating Controls...

Page 5: ...gs properly installed Do not operate this appliance if the smell of gas is present Turn off all gas supply valves and move to a remote location to call your manufacturer service The technical content...

Page 6: ...ed such that the flow of combustion and ventilation air will not be obstructed For servicing manufacturer recommends 6 clearance from rear of the appliance to wall Install adjustable legs one on each...

Page 7: ...burners Additionally 1 The gas supply line used to connect the charbroiler to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply...

Page 8: ...strongly recommended The shut off valve must be installed between the gas supply piping and the gas pressure regulator It is the responsibility of the gas piping installer to identify the code require...

Page 9: ...ain lit ADJUST BURNER FLAME Remove all burner control knobs then remove the front panel Turn an individual burner on The right knob controls the front burner the left knob controls the rear burner Loo...

Page 10: ...to smell near floor level because some gas is heavier than air and will settle to the floor For initial startup and any time the gas supply has been shut off it may take several minutes to light the p...

Page 11: ...ed at any time Cooking Recommendations Save energy by turning the temperature control knob OFF any time the griddle is not in use Gas burners provide full heat instantly making it unnecessary to leave...

Page 12: ...ler cabinet a Use a plastic scouring pad to remove any remaining food particles from the cabinet b Clean the cabinet with a soft damp cloth or sponge and mild detergent Rinse by wiping with a soft clo...

Page 13: ...ctors may be removed from burners for cleaning by removing the retaining wire Cleaned with a plastic scouring pad and mild detergent Dry thoroughly before reinstalling on burners Rinse by wiping with...

Page 14: ...r Remove burner and dry thoroughly Damaged temperature control Burner or other internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in...

Page 15: ...ice RESTAURANT _____________________________ LOCATION ___________________________ INSTALLATION DATE ________________________ TECHNICIAN ________________________ SERVICE COMPANY _______________________...

Page 16: ...Page 15...

Page 17: ...Page 16...

Reviews: