SATO SK-8300 Instruction Manual Download Page 9

 

Taking Measurements 

∙ 

Measurement with the trigger 

1.  Face the temperature measurement section to an object of measurement and pull the trigger. 

 

  The power turns on and a measured value is displayed on the larger temperature displaying area 

of the LCD. 

     

Note

: A measurement can be taken even a measurement or setting category is being selected. 

2.  A continuous measurement is taken if you keep pulling the trigger. 

     

Note

: “

SCAN”

 character blinks during a continuous measurement. 

3.  Once the trigger is released, the unit holds the last measured value for approximately 6 seconds 

then automatically turns off the power.(Auto Power-Off function) 

 

∙ 

Auto Measurement Function

 

 

It is possible to take a continuous measurement without keep pulling the trigger. 

1.  Face the temperature measurement section to an object of measurement and pull the trigger. 

 

  The power turns on and a measured value is displayed on the larger temperature displaying area 

of the LCD. 

2.  Select any one of following measurement mode categories: Normal, MAX, MIN, AVG or ΔT 

   

Note:

 Auto Measurement cannot be set during a Setting mode. 

3.  Press the   key. 

 

  “

AUTO

” is displayed on the LCD and a continuous measurement starts. 

 

 “

SCAN”

 character blinks during a continuous measurement. 

4.  Press the   key once more to end the Auto measurement. 

Caution:

 If  the  battery  power  runs  out  during  Auto  Measurement,  the  low  battery  mark  lights  on  and 

after 30 seconds, the power turns off automatically. 

 

Measurement Modes 

A  measured  value  is  displayed  on  the  larger  measurement  displaying  area  and  the  value  by  selected 

mode is displayed on the smaller one. 

Normal Mode:

   

This is a measurement mode for general measurements. A measured value is displayed in the larger 

measurement displaying area. The same value is displayed on the smaller one. 

∙ 

MAX Mode:   

The  “MAX”  character  lights  up  and  the  maximum  measured  value  is  displayed  in  the  smaller 

measurement displaying area.  A maximum value  is the highest temperature value taken since the 

MAX Mode is turned on. 

 MIN Mode: 

   

The “MIN” character lights up and the minimum measured value is displayed in the smaller 

measurement displaying area. A minimum value is the lowest temperature value taken since the MIN 

Mode is turned on. 

Summary of Contents for SK-8300

Page 1: ...nfrared Thermometer Model SK 8300 The SK 8300 complies with Portable Laser Applied Device of Consumer Product Safety Act and carries PSC mark 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http...

Page 2: ......

Page 3: ...asuring error or failure may occur resulting in a critical damage Never disassemble or modify the unit or use different types of batteries other than indicated as these actions may result in measuring...

Page 4: ...the unit was purchased Overview The SK 8300 is non contact type infrared thermometer which detects the infrared energy emitted from an object and converts it into a temperature reading The product can...

Page 5: ...measurement and alarm 6 Loop for wrist strap 7 Laser emitting window 8 Temperature measurement section lens 9 Battery compartment button Push this button to open the battery compartment cover 10 Meas...

Page 6: ...a stored data 8 Light up during T mode 9 Light up while setting emissivity 10 HAL Light up while setting upper threshold for alarm 11 LAL Light up while setting lower threshold for alarm 12 AUTO Ligh...

Page 7: ...r is pulled Open the battery compartment cover by pressing the battery compartment button Set the laser switch to ON The factory set is to ON Reinstall the cover and push in to fasten with a click The...

Page 8: ...ed mode at the time of turning the power OFF Normal Mode Measurement mode at normal MAX Mode To display a maximum value MIN Mode To display a maximum value AVG Mode To display an average value T Mode...

Page 9: ...gories Normal MAX MIN AVG or T Note Auto Measurement cannot be set during a Setting mode 3 Press the key AUTO is displayed on the LCD and a continuous measurement starts SCAN character blinks during a...

Page 10: ...Mode A measured value is displayed on the larger measurement displaying area and a setting value is displayed on the smaller one All setting values are stored even the battery is taken out DATA displa...

Page 11: ...isplay area is stored About Data Numbers Select a data number from 1 to 9 and A where the data is to be stored by using and keys The data numbering sequence is as follows DATA1 DATA2 DATA9 DATA A If a...

Page 12: ...he temperature measurements of unwanted parts resulting incorrect readings Emissivity All objects emit infrared radiation in accordance to surface temperature but the emissivity value can differ depen...

Page 13: ...eet the temperature value read from the contact type thermometer The emissivity found from this procedure could be used as a standard emissivity for the object Cautions on Measurement Measuring throug...

Page 14: ...lower than 30 C Trouble Shooting Trouble Possible cause Solution The power cannot be turned on The battery is exhausted Replace with a new battery Laser marker does not work The laser marker setting i...

Page 15: ...an alkali battery Backlight Standard Dimensions 51 W x 166 D x 200 H mm Weight approx 280 g with battery Materials Unit ABS resin Standard accessories Carrying case 9V battery Hand strap Warranty Poli...

Page 16: ......

Reviews: