8.1. 

USB Interface 

The magnetometer PMG2 can be directly connected with a computer through the 

USB cable supplied by the manufacturer.  

The program supplied with the instrument transmits data from the magnetometer 

to the external computer. 

8.2. 

Charger 

The charger is delivered with the instrument, allowing careful and optimum 

charging of the built-in lead-acid battery 12 V / 3.4 Ah, to use its full capacity and lifetime. 
The product is double insulated. 

The charger automatically sets the optimum charging mode according to the 

condition of the battery. There is no danger to damage the battery from overcharging. 

Operation: 

1.  Plug the connector of the charger cable in the connector on the lower right part of the 

instrument. 

2.  Switch on the charger by plugging it in. 
3.  The battery is charged when the pilot light turns off. 

8.3. 

Maintenance And Repair Work 

Under normal operating conditions, the magnetometer requires no special 

maintenance. Only the built-in lead-acid battery needs care. If the voltage drops under a 
certain level, the battery might be damaged, or the magnetometer might not operate 
correctly, so the instrument is switched off automatically. When the device is not used for 
a long time, it is still discharging and must be charged at least once a half-year.  

Because of the complexity of the instrument, it is strongly recommended not to 

make any interference with the electronics. 

In the case of a failure of the magnetometer, the customer should contact the 

distributor or the manufacturer. The service will be performed as soon as possible. 

8.4. 

Storage And Transportation 

The packed instrument can be stored and transported in the range of 

temperatures -

20° to 70°C and at the relative humidity of up to 90%. 

The built-in lead-acid battery should be checked and charged with the supplied 

charger at least once a half-year. 

8.5. 

Warranty 

The manufacturer provides a two-year warranty after the purchase of the proton 

magnetometer PMG2. Other information relating to the warranty is given in the warranty 
certificate. 

 

Summary of Contents for PMG-2

Page 1: ...2021 SatisGeo s r o 1 29 2021 PMG 2 User Manual...

Page 2: ...12 5 2 Tuning Of The Magnetometer 12 5 3 Setting The Backlight 14 5 4 Selection Of The Sensor Configuration 14 5 5 Walk Sample Rate Configuration 14 5 6 Setting The Time Interval To Switch Off 14 5 7...

Page 3: ...2 8 1 USB Interface 19 8 2 Charger 19 8 3 Maintenance And Repair Work 19 8 4 Storage And Transportation 19 8 5 Warranty 19 8 6 Accessories 20...

Page 4: ...ield WALK mode continually measures the magnetic field based on sensor configuration in three intervals 0 5s 1s 1 5s 2s 2 5s and 3s The possible sensor configuration is the same as in manual mode The...

Page 5: ...ght 3 2 kg including battery Sensor Dimensions dia 80 x 200 mm Weight 0 7 kg Operating temperature range 10 to 60 C Storage temperature range 20 to 70 C The maximum gradient 1000nT m means that if a c...

Page 6: ...l from the sensor and thus the size of the error of the measurement Figure 3 1 Post assembly for line measurement For measurements the sensor is mounted on a post which is assembled using up to five h...

Page 7: ...ue of the field measured in the location of the sensor connected to the Up sensor connector minus the value of the field measured in the location of the sensor connected to the Down sensor connector T...

Page 8: ...proportional to the measured magnetic field The entire measuring cycle is controlled by a microprocessor which computes the measured magnetic field and statistical error of the measurement from the va...

Page 9: ...parameters 1 MEASURE item sub menu serves to activates measurement The possible measurements are MANUAL WALK and AUTO See chapter 6 2 POSITION Item serves for the setting of a number of a profile line...

Page 10: ...ated in the setup menu item 5 S 08 04 28 DEVICE SETUP 1 BACKLIGHT 2 DATE TIME 3 OFF TIME 4 INFO 1 BACKLIGHT Item serves to switch the backlight on off or to set the time to elapse See chapter 5 3 2 DA...

Page 11: ...10...

Page 12: ...ivities of the operator on the keyboard or through the USB interface The interval can be set in the Setup menu item Time If the instrument does not display the above mentioned information even after r...

Page 13: ...d magnetic field To display the current tuning interval select the TUNE sub menu MANUAL SET item in the setup menu For the SINGLE mode the display shows for example S 08 04 28 SET TUNE Sensor UP 41600...

Page 14: ...00 43 800 nT 35 95 300 99 999 nT 18 43 500 45 800 nT Table 5 1 Tuning intervals A preliminary approximate setting of the tuning point can be performed on the basis of a magnetic field map see Figure 5...

Page 15: ...ttery the instrument is automatically switched off after elapsing the set time interval after the last activities of the operator on the keyboard Thus the deep discharge and the damage of the battery...

Page 16: ...and is changed by pressing 0 when the cursor is placed at the sign NEXT is used for switching among the items Line Pos and Step The modified data are stored in the memory by pressing ENTER Pressing ES...

Page 17: ...sensor is changed and the statistical error of the measurement increases To achieve the maximum signal the sensor must be oriented in the north south direction so the north mark on the sensor must po...

Page 18: ...displayed By pressing ESC the measured data is erased and the current position is displayed 6 5 Measuring In Walk Mode The WALK measure mode is selected in the MEASURE menu In this mode the instrument...

Page 19: ...mation To store the data the operator presses ENTER otherwise ESC canceling the measured value and the measurement on the point can be repeated The position of the next measurement is displayed in bot...

Page 20: ...netometer requires no special maintenance Only the built in lead acid battery needs care If the voltage drops under a certain level the battery might be damaged or the magnetometer might not operate c...

Page 21: ...cessing Unit Console 1 pcs Sensor 2 pcs Harness 1 set Foot Stick 1 pcs Middle Stick 4 pcs Anchor Ring with Ropes 1 set Tent Pin 3 pcs Interface Cable to PC 1 pcs Charger 1 pcs Instruction Manual 1 pcs...

Reviews: