34
VERSA IP
SATEL
4. When a prompt will be displayed asking you whether to remove the detector (type and
serial number of the detector will be displayed), press
.
6. Numeration of zones and outputs in the system
6.1 Numeration of zones
6.1.1 Hardwired zones
By default, the mainboard zones have numbers from 27 to 30. You can assign any numbers
within the 1 to 30 range to these zones (see the P
ROGRAMMING
manual). If number 0 is
assigned, the zone will not be supported.
The zones in expanders are numbered depending on the address which is set in them:
•
expander with address 12 (0Ch) – numbers from 7 to 14,
•
expander with address 13 (0Dh) – numbers from 15 to 22,
•
expander with address 14 (0Eh) – numbers from 23 to 30.
If a mainboard zone number coincides with a wireless zone number, the mainboard
zone will not be supported.
If an expander zone number coincides with a mainboard zone number or a wireless
zone number, the expander zone will not be supported.
6.1.2 Wireless zones
The numbers of wireless zones are defined when adding the wireless devices. You can
select any zone number which is not occupied by another wireless device.
6.2 Numeration of outputs
The control panel supports outputs having numbers from 1 to 12. The numbers of hardwired
and wireless outputs may coincide. The control panel will support them simultaneously.
6.2.1 Hardwired outputs
The hardwired outputs are assigned numbers automatically:
•
the outputs on control panel main board have numbers from 1 to 5,
•
the outputs in expander have numbers from 5 to 12.
6.2.2 Wireless outputs
The numbers of wireless outputs are defined when adding the wireless devices. The wireless
output number is identical to that of the wireless zone. This means that the wireless outputs
may be assigned numbers from 1 to 30, though
the control panel does not support the
outputs having numbers from 13 to 30.
7. Specifications
7.1 Control panel
Supply voltage .................................................................................... 18 VAC ±15%, 50-60 Hz
Recommended transformer ............................................................................................. 40 VA
Standby current consumption ........................................................................................ 120 mA