background image

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLER 
MANUAL 

 
 
 
 
 
 
 
 
 
 
 

SATEL sp. z o.o. 

ul. Budowlanych 66 

80-298 Gda

ń

sk  

POLAND 

tel. 58 320 94 00 

www.satel.eu 

versa_i_en 10/15 

     

Alarm Control Panel 

     

 Firmwa

re Versio

n 1.06 

Summary of Contents for Versa 10

Page 1: ...INSTALLER MANUAL SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 58 320 94 00 www satel eu versa_i_en 10 15 Alarm Control Panel Firmware Version 1 06...

Page 2: ...ications or repairs not authorized by the manufacturer shall void your rights under the warranty The SATEL s goal is to continually upgrade the quality of its products which may result in alterations...

Page 3: ...ROUBLE MEMORY UNTIL REVIEW option is disabled Zones A new option for the zone type 19 TROUBLE SIGNALING ON INTERNAL SIRENS Outputs New output function 22 ETHM GSM TROUBLE STATUS Keypads Support for ne...

Page 4: ...ring transmitter 20 5 9 Connecting the analog telephone line 21 5 10 Connecting the power supply and starting the control panel 22 5 10 1 Main power supply 22 5 10 2 Backup power supply 22 5 10 3 Cont...

Page 5: ...ones 30 6 2 Numeration of outputs 30 6 2 1 Hardwired outputs 30 6 2 2 Wireless outputs 30 7 Specifications 30 7 1 Control panel 30 7 2 VERSA LCD keypad 31 7 3 VERSA LCDM keypad 32 7 4 VERSA LCDR keypa...

Page 6: ...Single EOL and Double EOL configuration Maximum number of programmable zones 30 20 zone types NC type tamper input on the control panel mainboard Outputs 4 programmable hardwired outputs on the contr...

Page 7: ...lus module to be connected Operating the alarm system from mobile devices control of the alarm system checking the alarm system status Event log 2047 events Users 30 users Capability to assign to the...

Page 8: ...d reader VERSA LCDM WRL wireless LCD keypad with mechanical keys and built in proximity card reader supported by ACU 120 and ACU 270 controllers VERSA LED hardwired LED keypad with mechanical keys The...

Page 9: ...bidirectional wireless devices to be used in the alarm system INT E CA 64 E CA 64 EPS Zone expander Adds 8 programmable hardwired zones to the security system INT O INT ORS CA 64 O CA 64 OPS Output ex...

Page 10: ...uld not exceed 1 V as against the output voltage In order to guarantee correct functioning of the system components it is important that resistance and capacitance of the signal wires be as low as pos...

Page 11: ...ttery connection cables red black RS 232 TTL port RESET pins for emergency starting the control panel see Emergency procedure of the control panel start up p 23 DIALER LED Indicates the status of cont...

Page 12: ...on ground OUT1 OUT2 programmable high current outputs 12 V DC voltage is always present at the terminal The terminal is either shorted to or disconnected from the common ground depending on the output...

Page 13: ...vice to the expander bus if conductors with 0 5 mm diameter are used CLK DTA COM Distance Number of wires up to 300 m 1 1 1 300 600 m 2 2 2 Table 1 For most devices to be connected to the communicatio...

Page 14: ...keypad terminals to the corresponding terminals of the control panel see Fig 5 7 Close the keypad enclosure Fig 5 Connecting keypads to the control panel 5 5 2 Connecting Ethernet module Fig 6 Connect...

Page 15: ...is impossible Fig 8 Connecting the INT RX S expander to the control panel Fig 9 Setting address in the INT RX S INT RX expander 5 5 4 Connecting 433 MHz wireless system controller One VERSA MCU contro...

Page 16: ...250 controller to the control panel One ACU 120 ACU 270 ACU 100 ACU 250 controller can be connected to the control panel The controller enables ABAX keyfobs to be assigned to the users up to 30 keyfo...

Page 17: ...ACU 270 ACU 100 ACU 250 controller is connected to the control panel installation of the VERSA MCU controller in the system is impossible Fig 13 Setting the DIP switches in the ACU 120 ACU 270 contro...

Page 18: ...MMING manual Expander address decimally hexadecimally Zone numbers 12 0C 7 14 13 0D 15 22 14 0E 23 30 Table 2 5 5 7 Connecting the hardwired output expander One INT O INT ORS CA 64 O CA 64 OPS expande...

Page 19: ...ting proximity card arm disarm devices Up to 6 INT CR INT IT INT IT 2 devices can be installed in the system Addresses from the 16 10h to 21 15h range should be set in the devices All the proximity ca...

Page 20: ...in both devices Fig 21 Setting address in the INT VG module CA 64 SM expander Recording of voice messages is disabled switch 8 in OFF position Connect the CLK and DTA terminals INT VG wires CA 64 SM...

Page 21: ...per R R1 R2 5 6 1 End of line resistors For the zones on the control panel mainboard and in the expanders identified by the control panel as CA 64 Ei and CA 64 EPSi the EOL resistor value is programma...

Page 22: ...3 contains description of the connector contacts in the NOKTON NR2 DSC transmitter used for connecting to the VERSA control panel Contact number Description Connection method 2 alternating voltage ch...

Page 23: ...rked T 1 R 1 Hence the telephone line should be connected to the control panel using a four wire cable When connected in this manner the control panel will be able to completely capture the line for t...

Page 24: ...e g by indicating the fuse which protects the control panel supply circuit Never connect two devices with power supply unit to one transformer Before connecting transformer to a circuit from which it...

Page 25: ...dure when reconnecting the power supply 5 10 4 Emergency procedure of the control panel start up If the control panel fails to start properly keypads are not supported codes are not accepted by the co...

Page 26: ...it will only allow setting addresses in the wired keypads 1 Enter the service code by default 12345 and press the key 2 Press in turn the keys The service mode will start 3 Press in turn the keys The...

Page 27: ...ification of devices connected to the bus Devices connected to the communication bus will not be properly supported unless they have been identified by the control panel Identification of the devices...

Page 28: ...nal received by device controller may not be lower than 40 If the radio signal level at the planned installation place is too low select another installation location Sometimes it is sufficient to mov...

Page 29: ...rite button to write the new wireless device data to the controller these data will not be written after clicking on the button in the main menu LCD keypad You can add ABAX wireless devices in the ser...

Page 30: ...up and controller identification by the control panel Before installation of the detector register it in the controller and check if transmissions from the detector located at the planned installation...

Page 31: ...ntion to add a detector 4 Using the and keys select the zone to which the detector is to be assigned and then press 5 The new name of the zone will be displayed You can change it Press to save the nam...

Page 32: ...other wireless device 6 2 Numeration of outputs The control panel supports outputs having numbers from 1 to 12 The numbers of hardwired and wireless outputs may coincide The control panel will support...

Page 33: ...DC Hardwired programmable zones VERSA 5 5 VERSA 10 10 VERSA 15 15 Maximum number of programmable zones 30 Hardwired programmable outputs 4 Maximum number of programmable outputs 12 Power supply outpu...

Page 34: ...ge 10 55 C Maximum humidity 93 3 Enclosure dimensions 139 x 124 x 22 mm Weight 236 g 7 4 VERSA LCDR keypad Supply voltage 12 V DC 15 Standby current consumption 30 mA Maximum current consumption 65 mA...

Page 35: ...6 15 Manual version Introduced changes 10 15 Information on the number of output functions has been updated p 4 Information on INT TSH keypad has been added p 6 Information on VERSA LCDR keypad has be...

Page 36: ......