Programming the control panel settings will only be possible after completion of the above
steps.
5.11 Programming addresses for the hardwired keypads
Each keypad connected to the control panel must have an individual address set within the
0 to 5 range. By default, address 0 is set in all wired keypads. When started with factory
default settings, the control panel will support all keypads connected to the bus, irrespective
of what addresses are set in them. Thus it is possible to set correct individual addresses in
the keypads.
Remember to program an individual address if a new keypad is connected to the
already functioning alarm system.
5.11.1 Programming the address by means of the service function
The address programming function can be started from either a wired or wireless
keypad, but it will only allow setting addresses in the wired keypads.
1. Enter the service code (by default 12345) and press the
key.
2. Press in turn the
keys. The service mode will start.
3. Press in turn the
keys. The K
EYPADS ADDR
. function will start. All
LEDs designated with icons will start blinking in keypads and information on the current
address will be presented by means of:
LCD: displayed message – see Fig. 26,
LED: rapid blinking of the LED designated with the number corresponding to the keypad
address (for address 0 – LED 30) – see Fig. 27.
n=0...5
currently set keypad
address
Fig. 26. Programming LCD keypad address.
Fig. 27. Programming LED keypad address. LEDs designated with numbers from 1 to 5 and
30 are used for address presentation (30 – for address 0). The LED corresponding to the
current address is blinking rapidly, the other ones are lit.
4. In the keypad in which a new address is to be set, press the key number corresponding to
the new address. The address change will be confirmed by four short beeps followed by a
long one.