SATELLINE-M3-TR8
SATELLINE-M3-TR9
Integration Guide, Version 1.7
11
2
TECHNICAL SPECIFICATIONS
2.1
Absolute maximum ratings
Absolute maximum ratings for voltages on different pins are listed in the following table.
Exceeding these values will cause permanent damage to the module.
Parameter
Min
Max
Voltage at VCC_IN
0 V
+5 V (TR8), +6V (TR9)
Voltage at ENA_MOD
0 V
+6 V
Voltage at VCC_IO
0 V
3.75 V
Voltage at digital inputs (except ENA_MOD)
0 V
3.75 V
Voltage at digital outputs
0 V
3.75 V
Note. All voltages are referenced to GND.
2.2
DC electrical specifications
Recommended operating conditions:
Parameter
Condition
Min
Max
Units
VCC_IN (TR8)
4.0 V is considered nominal
4.0
1
N5%
V
VCC_IN (TR9)
3.5
5.5
V
ENA_MOD, Vlow
0
0.2
V
ENA_MOD, Vhigh
1.2
VCC_IN
V
VCC_IO
1.8
3.3
V
Logic input, Vlow
1.8 V<VCC_IO<3.3V
0
0.3V
V
Logic input, Vhigh
1.8 V<VCC_IO<3.3V
0.9*VCC_IO
VCCIO
V
Logic output, Vlow
1.8 V<VCC_IO<3.3V
0
0.5
V
Logic output, Vhigh
1.8 V<VCC_IO<3.3V
0.6*VCC_IO
VCCIO
V
Logic output, max
current
All logic output except
STAT pin.
-
4
mA
Logic output, max
current, STAT pin
-
12
mA
1
Meets the ETSI requirements on given operating voltage range. Exceeding the values might drive the