10 INT-TSG
SATEL
Show viol. zones
[Zone violation] – with this option enabled, violating the CHIME signal
triggering zone result additionally in the zone name being displayed.
Auto-Arm delay countdown
[Auto-arm delay] – with this option enabled, the auto-arm delay
countdown in partition is signaled acoustically.
Show disarm messages
[Show disarming] – if this option is enabled, the keypad will inform
about disarming with a displayed message at all times. If the option is disabled – only in
case of disarming from the given keypad.
Show arm messages
[Show arm] – if this option is enabled, the keypad will inform about
arming with a displayed message (irrespective of how the system was armed).
Quick control
[Control (8#)] – if this option is enabled, the O
UTS CONTROL
user function can
be started without entering the user code:
– after tapping the
icon on the main screen, if no macro command is assigned to the
group;
– after tapping and holding the
icon on the main screen for about 3 seconds, if at
least one macro command is assigned to the group;
– from the terminal, after you tap in turn the
and
keys.
Zones
For each of the keypad zones can be defined whether it will be used or not.
Auto-backlight
The keypad can be woken up after occurrence of a specified event in the system: starting the
entry delay countdown in a selected partition, or violating a selected zone.
Wake-up
You can define how the keypad will respond to the wake-up (after a tap on the screen by the
user or occurrence of a specified event in the system):
Status screen
– status screen will be displayed.
Menu screen
– main screen will be displayed.
Disarming
– if at least one partition managed by the keypad is armed, the authorization
screen will be displayed (after entering the code and tapping
, and depending on the
system state: the partition(s) will be disarmed / partition selection screen will be displayed /
“Alarm clearing / Disarming” screen will be displayed). If none of the partitions is armed,
the main screen will be displayed.
Photo frame
– if this option is enabled, the following will be displayed after 10 minutes of
keypad inactivity:
slide show
– if there are at least two pictures on the memory card and the value of
C
HANGE PICTURE EVERY
parameter is different from 0,
clock
– if there are one or no pictures on the memory card or the value of C
HANGE PICTURE
EVERY
parameter is 0.
If this option is disabled, the screen will go blank after 10 minutes of keypad inactivity.
Tamper signaled in part.
[Tamper in part.] – partition where alarm will be triggered in the
event of keypad tamper (opening the enclosure or disconnecting keypad from the bus).