6 ETHM-1
Plus
SATEL
Fig. 4. Wiring diagram of the cable connecting RS-232 ports of ETHM-1 Plus module and
INTEGRA / INTEGRA Plus control panel with RJ type connector socket.
6 Configuring the settings
The module settings differ, depending on the control panel to which the module is connected.
Names of parameters and options from the DLOADX program are used in this manual. When
a parameter or an option is described, you will find in the square brackets their name
displayed on the keypad.
6.1 Module connected to INTEGRA / INTEGRA Plus control panel
You can configure parameters and options of the module using:
DLOADX program:
“Structure” window
“Hardware” tab
“Keypads” branch
[module name],
LCD keypad:
S
ERVICE MODE
S
TRUCTURE
H
ARDWARE
LCD
KEYPADS
S
ETTINGS
[module name].
All settings you can configure only by means of the DLOADX program.
If the module has been identified as “ETHM+GSM” (the INT-GSM module is connected
to the ETHM-1 Plus module), the INT-GSM module will take over tasks from the
ETHM-1 Plus module if the Ethernet connection is lost. These tasks are performed via
GPRS. Therefore many options and parameters apply to both modules. This should be
borne in mind when configuring the settings.
6.1.1 ETHM-1
Name
– individual name of the device (up to 16 characters).
Tamper signaled in part.
[Tamper in part.] – partition where alarm will be triggered in the
event of module tamper.
INT-GSM options
Options applicable to the INT-GSM module are available if the INT-GSM module is
connected to the ETHM-1 Plus module (the module is identified as “ETHM+GSM”).
SIM 1
/
SIM 2
[SIM1 / SIM2] – if this option is enabled, the given SIM card is supported by the
INT-GSM module. Disable the option, if the given card is not to be used. Disabling the
option will prevent unnecessary reporting of troubles related to that card.