32 ETHM-1
Plus
SATEL
Required settings of the GUARDX program for direct communication with the module:
programmed: number of TCP port used for communication and data encryption key
(GUARDX
KEY
).
1. In the startup window (Fig. 15), “Connection” field, select “TCP/IP: GUARDX<-ETHM/INT-
GSM”, and then click on the “Start” button.
2. Send to the INT-GSM module the following SMS message:
xxxx=
(“xxxx” – the control command to initiate establishment of communication with
GUARDX program) – the module is to connect to the computer address programmed in
the module,
xxxx=aaaa:p=
(“xxxx” – the control command to initiate establishment of communication
with GUARDX program; “aaaa” – address of the computer with GUARDX program (IP
address or domain name); “p” – TCP port) – the module is to connect to the computer
whose address has been given in the SMS message and use for communication the
TCP port given in the SMS message.
3. In the window that will be displayed after establishing communication, enter the code of
administrator / user of the control panel.
7.1.5 Establishing connection via the SATEL server
Required settings of the module:
enabled
C
ONNECTION VIA
S
ATEL SERVER
option.
Required settings of the GUARDX program for communication via the SATEL server:
programmed: ID number assigned to the module by the SATEL server (ETHM-1 ID), MAC
address of the module (ETHM-1 MAC) and data encryption key (S
ERVER KEY
).
1. In the startup window (Fig. 15), “Connection” field, select “TCP/IP: SATEL server”, and
then click on the “Start” button.
2. In the window that will be displayed after establishing communication, enter the code of
administrator / user of the control panel.
7.2 Web browser
Required settings of the module:
enabled WWW option,
programmed data encryption key (GUARDX
KEY
).
programmed the number of TCP port which will be used for communication with the web
browser (WWW
PORT
),
programmed the number of TCP port which will be used for communication with the JAVA
application in the web browser (P
ORT
).
The Java Virtual Machine must be installed on your computer. You can download it from
www.java.com
It is recommended that the 32-bit version of Java Virtual Machine be installed.
1. Start the web browser.
2. In the address field, enter the IP address of ETHM-1 Plus module, and then press
ENTER.
If a port other than 80 is to be used for communication between the module and the
web browser, the address entered must be followed by a colon and the port number.
3. When the login page displays (Fig. 19), enter in the corresponding fields:
data encryption key (GUARDX
KEY
),