CA-64 DR
SATEL
7
Arming
[Reader A arm./Reader B arm.] – this option defines whether the partition can be
armed by using the DALLAS chip. Hold the chip at the reader to arm the partition.
INTEGRA
Hardware signaling of readout
– activation of this option will start the chip code readout
signaling which is independent of the control panel.
INTEGRA
Alarm – 3 incorrect codes
– with this option enabled, alarm will be generated after three
attempts to read in an invalid DALLAS chip.
INTEGRA
Control BI
output
– reading the code of chip assigned to the "
Bi output control
" type of
codes will control the output type 25 (BI
S
WITCH
) in the given partition (if the code is
authorized to access the given partition and is included in the list of module users).
Control MONO
output
– reading the code of chip assigned to the
"Mono output control
" type
of codes will control the output type 24 (MONO
S
WITCH
) in the given partition (if the
code is authorized to access the given partition and is included in the list of module
users).
Partition blocking
– reading the chip of the guard or a user having the
"Temporary partition
blocking"
type of code
when the partition is armed will temporarily block the time of
entry in the partition the module is assigned to. The bypass duration is determined in
the partition parameters (for the guard) or in the user code parameters.
Guard control
– reading the chip of the user having the "
Guard
" type of code will be
recorded as completion of the round.
Signaling
– options related to signaling by LEDs of the reader or by the buzzer connected to
expander.
INTEGRA
Alarm signaling (fixed time)
– acoustic alarm signaling in the given partition (through the
total duration of alarm).
Alarm signaling (until canceled)
[Alarm (latch)] – acoustic alarm signaling in the given
partition until the alarm is cleared.
Signaling entry delay
– acoustic signaling of the countdown of entry delay time.
Signaling exit delay
– acoustic signaling of the countdown of exit delay time.
Auto-Arm delay countdown
– acoustic signaling of auto-arming delay countdown in the
group to which the module is assigned.
No auto-reset after 3 tampers
– each expander will automatically disable its tamper alarm
function after three consecutive (not cleared) tamper detection alarms, which prevents
the same events from being saved repeatedly in the control panel memory. This option
allows the blocking function to be deactivated.
Open door if fire
[Doors on fire] – control mode for the door blocking during fire alarm:
−
no
– fire alarm has no effect on the door blocking,
−
Partition fire alarm
– fire alarm in the partition will unblock the door controlled by the
module,
−
Object fire alarm
– fire alarm in the object will unblock the door controlled by the
module,
−
fire alarm
– fire alarm in the system will unblock the door controlled by the module.
6. Signaling
The mode of acoustic/optical signaling is conditional upon the alarm control panel program.
The expander has two outputs to control the LEDs' status and one output to control audible
signaling. The DALLAS chip readers come with a built-in two-color LED. It is also possible to
connect extra LEDs or a buzzer to the expander.