Satel CA-64 DR Manual Download Page 4

 SATEL 

CA-64 

DR 

4

2.  Call the "

Expander identification

" function in the LCD keypad (

Æ

Service mode 

Æ

Structure 

Æ

Hardware 

Æ

Identification). The identification completed, the LED indicating 

communication with the alarm control panel will start blinking. 

Note: 

In the process of identification, the control panel writes to the module memory 
a special  (16-bit)  number intended to detect the module presence in the system. 
Replacement of the expander with another one (even having the same address set up 
on the switches) without a new identification will trigger an alarm (module tamper – 
verification error). 

3.  Using the LCD keypad or computer (DLOAD64 or DLOADX program, depending on the 

control panel type), perform programming of the module functions and assign the users 
authorized to use the given reader. 

4.  Save the module settings in the control panel memory. 

4.  Description of expander operation  

The expander can simultaneously interact with two heads (designated in this manual with the 
letters 

A

 and 

B

), which read out the unique code of a DALLAS chip. To use the chip, touch 

the head socket with it and press it in slightly, so as to close the expander electric input 
circuit. 
Touching the reader with the chip will be recognized by the expander similarly as the entry of 
password from the partition keypad, confirmed by pressing the 

 key. Holding the chip (for 

about 3 seconds) will be recognized as the entry of password from the partition keypad, 
confirmed by pressing the 

 key. The way of reaction to touching the reader with the chip 

or to holding the chip depends on the expander settings. By using the DALLAS chip you can: 

  control the expander relay. To perform the relay control, touch the reader with the chip. 

The relay can be used to control the door electromagnetic lock, latch, lighting, actuating 
devices (ventilation, pumps, etc.). The mode of relay operation depends on the 
programmed function. 

 disarm the system and clear alarms. Disarming/alarm clearing takes place when the 

reader is touched with the chip, unless the "ON if partition armed " function is selected for 
the relay. If this is the case, the chip must be held longer. 

  arm the partition (only INTEGRA control panels). In order to do so, activate the "Arming" 

option for the selected reader and held the chip longer. 

Having received the DALLAS chip code from the reader, the expander will send the code to 
the alarm control panel. The panel will verify whether the user of the particular chip is 
authorized to operate the expander. Information on positive or negative verification is sent to 
the expander, and from there – to the reader, which can signal accordingly by means of 
LEDs whether the command has been carried out or rejected (the way of signaling depends 
on the control panel firmware and is described below in this document). Additionally, the 
signaling can be effected by means of external LEDs or a buzzer connected to the expander. 
If the verification is positive, the expander will perform the command according to its 
preprogrammed settings. 
The expander has the 

ON

 

input 

to control operation of the relay independently of the 

readers. The relay can be controlled by means of this input in the same way as provided for 
the heads. For example, this input can be used instead of the head B to open the door when 
leaving the room. In the normal state, the common ground (0V) should be connected to the 
ON input. In order to activate the relay, disconnect the input from the ground. It is possible to 
connect e.g. an NC type monostable switch or a remote control set to the ON input. 
Performance of the relay control function through the head A will generate a "User access" 
type of event, and through the head B – the "User exit" type of event in the system. Control of 
the ON input will not be recorded in the memory of events. 

Summary of Contents for CA-64 DR

Page 1: ...e in the module functions is possible only in case of interact with control panels of INTEGRA 1 Module description Figure 1 Diagrammatic view of the module electronics board Legend 1 LED indicator of...

Page 2: ...should be shorted to ground DRZWI door status control input NC if not used it should be shorted to ground The RESET pins are used in the manufacturing process and should not be shorted 1 1 DIP switch...

Page 3: ...nostable switch the leads of that button are to be connected to the terminals ON and COM 7 Connect the leads of the tamper contact on expander housing to the terminals TMP and COM Where two expanders...

Page 4: ...ing devices ventilation pumps etc The mode of relay operation depends on the programmed function disarm the system and clear alarms Disarming alarm clearing takes place when the reader is touched with...

Page 5: ...hip readers Name the option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows Service mode Structure Hardware Expanders Names expander sele...

Page 6: ...ition to which the module is assigned is armed unauthorized opening of the door will trigger the alarm and can be additionally signaled on the output type 94 ALARM UNAUTHORIZED DOOR OPENING Max door o...

Page 7: ...ling options related to signaling by LEDs of the reader or by the buzzer connected to expander INTEGRA Alarm signaling fixed time acoustic alarm signaling in the given partition through the total dura...

Page 8: ...g situations can be signaled acoustically Alarm in partition continuous beep Fire alarm one long beep every second Countdown of entry delay short beeps every 3 seconds Countdown of exit delay long bee...

Page 9: ...V 14V DC Maximum current consumption without heads 70mA Maximum relay switchable voltage AC 250V Maximum relay switchable current 2A Environmental class II Operating temperature range 10 C 55 C Dimens...

Page 10: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...