DLOAD10 program 

The  DLOAD10  program,  delivered  with  the  control  panel,  is  designed  for  programming  the 
CA-5, CA-6, CA-10 control panels, as well as the RX-2K, RX-4K and RE-4K radio controllers, 
the  GSM-4  module  and  the  ACU-100  wireless  system  controller,  from  the  computer. 
Additionally, the program makes it possible to create: documentation of alarm systems, sets 
of programmed system parameters for various configurations  ("patterns" which facilitate the 
programming  of  new  systems),  event  sets  for  each  system.  It  also  enables  to  remotely 
operate the control panel in the same way as with the keypads.  
The  program  is  designed  for  IBM  PC/AT  compatible  computers.  It  works  in  any  computer 
hardware configuration in the

 WINDOWS

 (9x/ME/2000) environment. It is recommended that 

the program be installed on the computer hard disk. 
The control panel communicates with the computer through the RS-232 (TTL) port or via the 
telephone  line.  For  telephone  communication  with  the  panel,  the  program  uses  a  modem 
controlled  by  one  of  the  COM  ports  (internal  or  external),  compatible  with  the  HAYES 
"AT Command"  standard.  Communication  with  the  control  panel  is  possible  in  the 

CCITT V.21

  or 

BELL 103

  standards  (at  300  Bps).  As  the  control  panel  transmits  data  only 

with a speed of 300 bauds, the modem must support this speed of operation. 

Usually  a  suitable  modem  configuration  is  necessary:  300  bps  speed  and  disabled 
function of negotiating the transmission standard.  

In  order  to  install  the  program,  run  the 

D10setup.exe 

program  from  a  CD-ROM  delivered 

with the control panel. When installation is completed, you can start the program. Access to 
the program is protected with an 

access code

. After installation, the code is 

[1][2][3][4]

 and 

can  be  changed  to  any  sequence  of  16  alphanumeric  characters.  As  long  as  it  is  set  by 
default,  you  can  start  the  program  (with  default  code  [1][2][3][4])  by  pressing  the  „ENTER” 
key (no access code need to be entered).  
Having started the program, you should choose in the computer a proper configuration and 
initialize  the  work  of  RS  port  or  modem  by  means  of  which  the  control  panel  will  be 
programmed.  By  default,  the  program  opens  the  CA-10  window.  Than  you  can  select  the 
CA-6 control panel and start the connection (either remote or local). 
A HELP system, which facilitates operating of the DLOAD10 and programming of the control 
panel  parameters,  is  provided.  The  system  is  accessible  from  the  „

HELP

”  menu,  or  by 

pressing  the 

F1

  key  on  the  computer  keyboard.  To  get  an  instant  access  to  more  detailed 

information, first select the required element in the program window (by clicking on it with the 
left mouse button), and then press the F1 key. 

Program configuration for communication with the control panel  

In order to begin configuration, click on the 

 icon to open the „

Configuration

” window. 

The  „

Port  RS-232

”  tab  permits  selecting  the  computer  port  number  in  the  case  of  direct 

programming  through  the  panel  RS  port.  If  the  control  panel  is  being  programmed  by 
means of the modem, select the „

Modem

” tab and click on the „

Details

” button.  

The  modem  communication  can  be  started  by  clicking  on  the 

  icon  (or  selecting  the 

„Modem” command from the „Communication” menu). The program will open a dialog box 
enabling  connection  to  be  established  and  will  prompt  the  further  course  of  action.  For 
details see the section „Remote programming – DOWNLOADING”. 
The type of control panel is recognized automatically on establishing connection, or can be 
selected through the „

File

” menu. 

Calling  the  function  of  reading  the  control  panel  data  (icon 

)  after  the  communication 

has been established may speed up the subsequent process of saving the changes in the 
control panel settings. 

Summary of Contents for CA-6-P

Page 1: ...Firmware Version 6 06 GDA SK ca6i_en 05 09 INSTALLER MANUAL...

Page 2: ...a fully discharged battery with voltage on unloaded terminals less than 11 V to the alarm panel In order to avoid equipment damage the fully discharged never used battery should be precharged by means...

Page 3: ...of Telephone Line 20 Connection of Voice Synthesizer 20 Connection of power supply 20 Starting the control panel 21 Entering service mode from pins 22 ACTIVATING SELECTED FUNCTIONS 22 Guard control f...

Page 4: ...s of telephone exchange signals which enables an alarm voice message to be sent after answering the call support of NOKTON radio messaging in PC16OUT format built in port RS 232 TTL the RJ socket is p...

Page 5: ...lation counters a zone violation code is sent to the station until the number of violations specified for that counter is exceeded programming in FS7 Then the violation triggers an alarm a zone alarm...

Page 6: ...olation of this zone during countdown of the exit delay will trigger an alarm Reaction time for each zone can be programmed within 0 016 s to 4 08 s For delayed zones an individual time delay can be s...

Page 7: ...larms the output starts on detecting any keypad alarm The output can remain active for a specified time from 01 to 99 seconds or from 01 to 99 minutes or until the alarm is cleared by the user During...

Page 8: ...mited to indicating the exit delay for specified partition 17 entry delay status the output is active during the entry delay countdown Operation of the output can be limited to selecting the entry del...

Page 9: ...med mode it functions similarly to the ARM STATUS output but it is activated right after exit delay starts not after changeover from the exit delay to the armed mode it can be used for example as indi...

Page 10: ...e one left by the deleted user Individual users may have the following authority levels 1 accessible all functions except creating and deleting users 2 accessible arming and disarming change of access...

Page 11: ...onnected to the station the control panel will suspend dialing the station number for 60 seconds and if the message is also to be transmitted by the dialer it will make the line available to the diale...

Page 12: ...top dialing the number for which connection cannot be established no answer permanently busy etc Messaging can be carried on until successful It is also possible to determine the maximum number of ret...

Page 13: ...e control panel Notification of the monitoring station will take place after communication with the computer is over 3 Establishing of communication from the control panel by calling the function 0 by...

Page 14: ...connected with a special cable manufactured by SATEL The cable includes a converter changing the signal into a standard corresponding to the RS 232 port in the computer 12 V 12 V The data can be tran...

Page 15: ...l system the stabilized voltage of the control panel power supply is 13 6 V to 13 8 V and is factory set battery status monitoring system with optional disconnection of the battery if discharged durin...

Page 16: ...n of the housing be careful so as not to damage the wires which will be passed through the hole in its back panel When the housing is secured you can install the control panel main board and proceed t...

Page 17: ...e inputs The keypad Z1 terminal is treated as zone 7 Z2 as zone 8 Provision is made for connecting additional keypads in parallel with the first one Each keypad should be connected to the control pane...

Page 18: ...nables the status of detector and its tamper contact to be monitored at the same time The detectors may be supplied from any of the electronically protected outputs OUT1 to OUT3 The output should be p...

Page 19: ...M 12V C TMP EOL NO 2 2k Fig 7 Example of connecting NO type detector in EOL configuration to control panel COM OUT3 DTA CLK CTL COM Z1 Z2 Z3 COM Z4 KPD COM CA 6 EOL NC 2 2k NC TMP COM 12V NC TMP Fig 8...

Page 20: ...T2 COM OUT3 COM 12 V LIMITER 2 2A LIMITER 2 2A LIMITER 2 2A LOAD LOAD LOAD KPD LIMITER 1 5A Fig 10 Connection of a load to high current outputs In the case of sirens which alarm after power is supplie...

Page 21: ...tter NEMROD system format PC16OUT In such a case it is necessary to change the operating mode of these outputs by activating a suitable option in the service function 5 During operation with the NOKTO...

Page 22: ...multicore cable This may result in damage to the system in case of a high voltage punch through from the telephone line Telephone terminals of the panel should be connected to PSTN analog lines only C...

Page 23: ...avoiding damage to the security system elements caused by possible installation faults Note Should it be necessary to completely disconnect the control panel power supply the mains and the battery re...

Page 24: ...he user passwords FS110 and or reset the event log FS108 Note Shorting the pins and power up alone will restore no parameters These operations will call up the service mode thus making it possible to...

Page 25: ...en the above parameters are correctly programmed and the alarm is triggered the on board LED designated as DIALER should go on which indicates that the panel has started telephone messaging with pulse...

Page 26: ...he list from the monitoring station operator the codes can be one digit the other character being 0 or two digit as required by the station the codes with inappropriate length may block communication...

Page 27: ...e transmission formats supported by the given station e g ambiguous names of the formats errors in the data entered into the control panel as well as poor quality of the telephone connections Often on...

Page 28: ...P mainboard Fig 14 Connecting control panel to modem for local mode programming Local communication connect the computer modem to the TIP and RING control panel terminals the telephone line must be di...

Page 29: ...s initialization error wrong command initializing the modem Correct initialization of the modem does not mean it is properly configured to work with the control panel The first initializing commands a...

Page 30: ...be changed to any sequence of 16 alphanumeric characters As long as it is set by default you can start the program with default code 1 2 3 4 by pressing the ENTER key no access code need to be entere...

Page 31: ...DLOAD10 DEFAULT SETTINGS Control panel configuration restore with FS107 function service code 12345 master code 1234 control panel password communication identifier 3175B9 computer password communica...

Page 32: ...all zones 480 ms output OUT1 audible signaling BURGLARY ALARM function operation time equal to global time polarity 12 V assigned to all zones output OUT2 visual signaling BURGLARY ALARM function ope...

Page 33: ...andby power supply recommended battery 12 V 7 Ah Battery charging current 350 mA Battery cut off voltage 10 5 V Battery cutout protection polymer fuse 2 5 A Operational temperature range 10 55 C Print...

Page 34: ...1x0 25 8 8 Ah AAv 1 25x 0 07x12 0 12x12 0 08x12 0 5x0 25 0 05x0 25 4 22 Ah Recommended standby power supply 12 V 7 5 Ah battery Assumed current consumption by a single detector 20 mA If the capacity...

Page 35: ...n telephone line public telephone line voice synthesizer see p 20 power supply outputs low current programmable outputs see p 19 programmable zones description of detectors connection see p 16 CTL inp...

Page 36: ...ed p 12 it requires a new cable now p 12 The schematic view of the CA 6 main board has been changed p 12 and 33 The figure of connection of the detectors to the control panel has been changes to a new...

Reviews: