6 APMD-250
SATEL
13. Replace the cover.
14. Configure the detector settings (sensitivity of PIR sensor, sensitivity of microwave sensor,
the way of operation in test mode, etc. – see the ABAX 2 / ABAX controller manual / the
INTEGRA 128-WRL control panel manual).
15. Start the test mode (see the ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL
control panel manual).
16. Check whether moving around within the detector coverage area will get the LEDs to
come on. Fig. 7 shows the maximum detection range and the creep zone of
a detector placed at a height of 2.4 m.
Fig. 7 shows the range of APMD-250 detector with the wide-angle (WD) Fresnel lens,
which is installed in the detector as standard one. You can change the detector
enclosure cover to install another lens instead. The SATEL product range includes
covers with the curtain (CT) lens as well as with the long-range (LR) lens.
17. End the test mode.