SATEL APMD-250
3
the battery life can be increased as much as fourfold. The option is only available in the
ABAX 2 system. The detector with “ECO” option enabled meets requirements of the
EN50131-2-4 standard for Grade 2.
Test mode
The test mode makes the detector testing easier, because the LED indicators are enabled.
How to start and end the test mode is described in the ABAX 2 / ABAX controller manual /
the INTEGRA 128-WRL control panel manual.
LEDs
The LEDs are flashing for about 40 seconds from inserting the battery, thus signaling the
warm-up of the detector. The LEDs also work in the test mode, in which they indicates:
periodical communication – short flash (80 milliseconds),
motion detection – ON for 2 seconds.
Supervision of motion detection system
When the motion detection system starts malfunctioning, the detector will report an alarm
during periodical communication. The alarm will keep going until the fault is cleared (long
violation).
Battery status control
When the battery voltage is below 2.75 V, information about low battery is sent during each
transmission.
In response to the battery voltage drop below 2.75 V, sensitivity of sensors in the
detector is automatically lowered to eliminate false alarms.
Electronics module
Do not remove the plastic cover from
the circuit board to prevent damage to
the components located on the board.
Do not touch the pyroelectric sensor,
so as not to soil it.
CR123A lithium battery.
microwave sensor.
LED indicator.
element not used.
tamper switch activated by cover removal.
PIR sensor (dual element pyrosensor).
On the other side of the electronics module is
a tamper switch activated by removing the
detector from the wall.