Satel APD-200 Manual Download Page 2

IMPORTANT 

The device should be installed by qualified personnel. 
 
Prior to installation, please read carefully this manual. 
 
Changes, modifications or repairs not authorized by the manufacturer shall void your rights 
under the warranty. 
 
The rating plate of the device is located on the enclosure base. 
 
 
 
 
 
 
 
 
 
 
 

SATEL aims to continually improve the quality of its products, which may result in changes in 

their technical specifications and software. Current information about the changes being 

introduced is available on our website. 

Please visit us at: 

http://www.satel.eu 

 
 
 
 
 
 
 

Hereby, SATEL sp. z o.o. declares that the radio equipment type APMD-250 is in 

compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity 

is available at the following internet address: www.satel.eu/ce 

 
 
 
 
 
The following symbols may be used in this manual: 

 - note, 

 - caution. 

 

Summary of Contents for APD-200

Page 1: ...APMD 250 Wireless dual technology motion detector Firmware version 1 00 apmd 250_en 01 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Page 3: ...disable the creep zone protection Ability to replace the lens with a curtain or long range one Encrypted two way radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system T...

Page 4: ...period shorter than 5 seconds this alarm can only be reported in the active mode see Operating modes after detecting a fault in the motion detection system after opening the tamper switch tamper alar...

Page 5: ...n detection system When the motion detection system starts malfunctioning the detector will report an alarm during periodical communication The alarm will keep going until the fault is cleared long vi...

Page 6: ...Fig 2 2 Move the electronics module down to unlock it and then remove it from the enclosure base Fig 3 3 Install the battery and add the detector to the wireless system see the ABAX 2 ABAX controller...

Page 7: ...ake screw holes in the enclosure base 10 Secure the enclosure base to the wall Fig 4 or the bracket fastened with screws to the wall or ceiling Fig 5 The wall plugs anchors delivered with the device a...

Page 8: ...anel manual 16 Check whether moving around within the detector coverage area will get the LEDs to come on Fig 7 shows the maximum detection range and the creep zone of a detector placed at a height of...

Page 9: ...SATEL APMD 250 7...

Page 10: ...8 APMD 250 SATEL...

Reviews: