The detector operating mode is turned on remotely. If the detector is used in the INTEGRA /
VERSA alarm system, the operating mode may depend on the partition state (partition
disarmed – passive mode; partition armed – active mode). For more information, refer to the
ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL control panel manual.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable in the detector the “ECO” option. When
the “ECO” option is enabled, the periodical communication takes place every 3 minutes. Thus
the battery life can be increased as much as fourfold. The option is only available in the
ABAX 2 system.
Test mode
The test mode makes the detector testing easier, because the LED indicator is enabled, and
the alarm is triggered by the glass breaking sound alone (the high-frequency sound). How to
start and end the test mode is described in the ABAX 2 / ABAX controller manual / the
INTEGRA 128-WRL control panel manual.
LED
The LED is flashing for about 3 seconds from inserting the battery,
thus signaling the warm-up of the detector. The LED also works in the
test mode, in which it indicates:
periodical communication – short flash (80 milliseconds),
registering a low-frequency sound – flash (500 milliseconds),
alarm – ON for 2 seconds.
Battery status control
When the battery voltage is below 2.75 V, information about low
battery is sent during each transmission.
Electronics board
Do not remove the electronics board from the enclosure to
avoid damage to the components on the board.
Fig. 1 shows the detector inside after opening the enclosure.
tamper switch.
CR123A lithium battery.
3. Selecting a mounting location
The detector is designed for indoor installation.
The detector microphone should be directed towards the protected glass, so the best
place to mount the detector is the wall opposite the protected glass.
The distance between the detector and the protected glass must not exceed the detection
range (6 m).
The detection range depends on the room acoustics. The shades, curtains, furniture
upholstery, acoustic tiles, etc. absorb the sound and adversely affect the detector
operating range.
It is not advisable to install the detector on the same wall on which the protected glass
pane is located, or in the vicinity of sound emitting devices, such as loudspeaker, bell, air
conditioner, etc.