background image

The AGD-200 detector enables detection of a break of plate, tempered and laminated glass. 
It is designed for operation within the ABAX 2 / ABAX two-way wireless system. This manual 
applies to the detector with firmware version 1.00 (or newer), which is supported by: 

 ABAX 

2: 

– ACU-220 

ACU-280 controller, 

–  ARU-200 repeater.  

 ABAX: 

–  ACU-120 / ACU-270 controller (firmware version 5.04 or newer), 
–  ARU-100 repeater (firmware version 2.02 or newer), 
–  INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware 

version of processor used to operate ABAX system 3.10 or newer). 

1.  Features 

  Advanced two-path sound analysis. 

 Adjustable 

detection 

sensitivity. 

  Encrypted two-way radio communication in the 868 MHz frequency band (AES standard 

for the ABAX 2 system). 

  Transmission channel diversity – 4 channels for automatic selection of the one that will 

enable transmission without interference with other signals in the 868 MHz frequency 
band (ABAX 2 system only). 

  Remote update of detector firmware (ABAX 2 system only). 

 Remote 

configuration. 

  Built-in temperature sensor (temperature measurement range from -10°C to +55°C). 

  “ECO” option for longer battery life (ABAX 2 system only). 

  Battery status control. 

 LED 

indicator. 

  Tamper protection against enclosure opening and removal from mounting surface. 

2.  Description 

Radio communication 

The detector connects to the controller / control panel at regular time intervals to provide 
information about its state (periodical communication). Additional communication may take 
place as a result of alarm (see “Operating modes”). 

Alarms 

The detector will report alarm: 

  after detecting a glass break (registering successively a sound of low frequency (impact) 

and a sound of high frequency (glass break) within less than 4 seconds), 

  after opening the tamper switch (tamper alarm). 

Operating modes 

Active

 – information about each alarm is sent immediately. 

Passive

 – only information about tamper alarm is sent immediately. This operating mode 

prolongs the battery life. 

Summary of Contents for AGD-200

Page 1: ...AGD 200 Wireless glass break detector Firmware version 1 00 agd 200_en 03 19 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...y improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type AGD 200 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is av...

Page 3: ...with other signals in the 868 MHz frequency band ABAX 2 system only Remote update of detector firmware ABAX 2 system only Remote configuration Built in temperature sensor temperature measurement range from 10 C to 55 C ECO option for longer battery life ABAX 2 system only Battery status control LED indicator Tamper protection against enclosure opening and removal from mounting surface 2 Descriptio...

Page 4: ...of the detector The LED also works in the test mode in which it indicates periodical communication short flash 80 milliseconds registering a low frequency sound flash 500 milliseconds alarm ON for 2 seconds Battery status control When the battery voltage is below 2 75 V information about low battery is sent during each transmission Electronics board Do not remove the electronics board from the enc...

Page 5: ...e consequences of incorrect installation of the battery The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection 1 Open the detector enclosure Fig 4 The enclosure opening tool shown in the illustration is included in the detector delivery set 2 Install the battery and add the detector to the wireless system see the ABAX 2 A...

Page 6: ...er manual the INTEGRA 128 WRL control panel manual 7 Place the INDIGO TESTER close to the protected glass and use it to generate a glass break sound If the detector LED comes on continue the installation Otherwise change the detection sensitivity see the ABAX 2 ABAX controller manual the INTEGRA 128 WRL control panel manual or select another installation location and repeat the test the level of s...

Page 7: ...ion range up to 6 m Complied with standards EN 50130 4 EN 50130 5 EN 50131 5 3 Environmental class according to EN50130 5 II Operating temperature range 10 C 55 C Maximum humidity 93 3 Dimensions 20 x 102 x 23 mm Weight 39 g ...