24 ACU-220
SATEL
devices taking up 8 positions, the system must reserve 16 zones and 16 outputs as well as 2
addresses. Table 4 shows an example of how to correctly register the same devices
(compare also Fig. 18). For 8 devices, the system has reserved 8 zones and 8 outputs as
well as 1 address.
INTEGRA / INTEGRA Plus
ACU-220
zones
outputs
It.
list of devices
No
device
No
device
1 APD-200 detector
17 APD-200 detector
17 unused/unavailable
2 APD-200 detector
18 APD-200 detector
18 unused/unavailable
3 AMD-200 detector
19 AMD-200 detector
19 unused/unavailable
4 AMD-200 detector
20 AMD-200 detector
20 unused/unavailable
5 AMD-201 detector
21 AMD-201 detector
21 unused/unavailable
6 ^
22 AMD-201 detector
22 unused/unavailable
7
23 unused/unavailable
23 unused/unavailable
8 ASP-200 siren
8
24 ASP-200 siren
24 ASP-200 siren
9 ^
25 ASP-200 siren
25 ASP-200 siren
10
26 unused/unavailable
26 unused/unavailable
11
27 unused/unavailable
27 unused/unavailable
12
28 unused/unavailable
28 unused/unavailable
13
29 unused/unavailable
29 unused/unavailable
14
30 unused/unavailable
30 unused/unavailable
15
31 unused/unavailable
31 unused/unavailable
16
8
32 unused/unavailable
32 unused/unavailable
Table 3.
INTEGRA / INTEGRA Plus
ACU-220
zones
outputs
It.
list of devices
No
device
No
device
1 ASP-200 siren
17 ASP-200 siren
17 ASP-200 siren
2 ^
18 ASP-200 siren
18 ASP-200 siren
3 APD-200 detector
19 APD-200 detector
19 unused/unavailable
4 APD-200 detector
20 APD-200 detector
20 unused/unavailable
5 AMD-200 detector
21 AMD-200 detector
21 unused/unavailable
6 AMD-200 detector
22 AMD-200 detector
22 unused/unavailable
7 AMD-201 detector
23 AMD-201 detector
23 unused/unavailable
8 ^
8
24 AMD-201 detector
24 unused/unavailable
Table 4.