Edition du 29/03/12 12/16 U508113-e Révision 4
7.3. 3 ways valve operation
1. Insert a ticket in the ticket printer
2. Choose the outlet pipe required (either via the front (B) or the back (A) of the valve) by using the lever (1).
a) lightly pull the lever (1) and position it in relation to the outlet pipe required (position A or B) and put the
lever (2) in a open position 0.
b) block the ticket printer by turning the meter head button one full turn.
This operation results in :
- The ticket being locked in the printer
- Printout on the ticket of a first line of figures
- Resetting of the figures indicated on the register
- The selected setting of the 3-way-valve being locked
3. Delivery can now take place, or flow rate modified, using the control lever (2) of the 3 ways valve.
At the end of delivery the user turns the meter head push button a full turn which results in :
- A second row of figures being printed on the ticket
- The ticket is released
- The 3 way valve is released.
(without modification of the information display on the register)
The complete cycle can begin again.
F
O
F
O
B
A
1
2