121
EN
Operating Instructions SATAjet 1000 B (RP/HVLP)
Operating Instructions SATAjet 1000 B (RP/HVLP)
Notice!
If the gun input pressure does not reach the necessary level, increase
the pressure in the compressed air circuit.
Too much input pressure results in high trigger forces.
■
Pull trigger guard
[1-11]
right back.
■
Adjust the gun input pressure to one of the following settings
[3-1]
,
[3-2]
,
[3-3]
to
[3-4]
. Note the maximum gun inlet pressure (see chap-
ter 2).
■
Bring the trigger guard to the starting position.
Adjust the material flow
Notice!
Wear at the fluid tip and paint needle is lowest when the material flow
control is wide open. Select fluid tip size according to the material and
working speed.
Fully variable adjustment of the material flow and thus the needle stroke
is possible with the adjusting screw as shown in Figs.
[4-1]
,
[4-2]
,
[4-3]
and
[4-4]
.
■
Loosen counter nut
[1-4]
.
■
Pull trigger guard
[1-11]
right back.
■ Adjust material flow at the adjusting screw
[1-3]
.
■
Tighten counter nut by hand.
Adjust spray fan pattern
Fully variable adjustment of the spray fan pattern is possible using the
round / flat fan control
[1-2]
to achieve a round fan.
■ Adjust the spray fan pattern by regulating the round and flat fan control
[1-2]
.
■
Turn to the right
[5-2]
– for a round fan
■
Turn to the left
[5-1]
– for a flat fan
Start spraying process
■
Observe correct spray distance (see chapter 2).
■
Pull trigger guard right back
[6-2]
and hold spray gun at 90° to the
surface being sprayed
[6-1]
.
■ Ensure there is sufficient spraying air feed and material supply.
■
Pull trigger guard
[1-11]
back and start spraying process. Adjust mate-
rial flow and spray fan pattern if necessary.
143842-BAL-SATAjet 1000 B.indb 121
31.10.2019 13:23:12
Summary of Contents for satajet 1000 b
Page 44: ...143842 BAL SATAjet 1000 B indb 44 31 10 2019 13 23 07 ...
Page 60: ...143842 BAL SATAjet 1000 B indb 60 31 10 2019 13 23 08 ...
Page 96: ...143842 BAL SATAjet 1000 B indb 96 31 10 2019 13 23 10 ...
Page 114: ...143842 BAL SATAjet 1000 B indb 114 31 10 2019 13 23 11 ...
Page 170: ...143842 BAL SATAjet 1000 B indb 170 31 10 2019 13 23 14 ...
Page 250: ...143842 BAL SATAjet 1000 B indb 250 31 10 2019 13 23 19 ...
Page 270: ...143842 BAL SATAjet 1000 B indb 270 31 10 2019 13 23 20 ...
Page 290: ...143842 BAL SATAjet 1000 B indb 290 31 10 2019 13 23 21 ...
Page 326: ...143842 BAL SATAjet 1000 B indb 326 31 10 2019 13 23 23 ...
Page 386: ...143842 BAL SATAjet 1000 B indb 386 31 10 2019 13 23 27 ...
Page 464: ...143842 BAL SATAjet 1000 B indb 464 31 10 2019 13 23 32 ...
Page 500: ...143842 BAL SATAjet 1000 B indb 500 31 10 2019 13 23 34 ...
Page 502: ...143842 BAL SATAjet 1000 B indb 502 31 10 2019 13 23 35 ...
Page 503: ... 10 143842 BAL SATAjet 1000 B indb 503 31 10 2019 13 23 36 ...
Page 504: ... 11 Loctite 242 143842 BAL SATAjet 1000 B indb 504 31 10 2019 13 23 36 ...
Page 505: ... 14 12 143842 BAL SATAjet 1000 B indb 505 31 10 2019 13 23 37 ...
Page 508: ... 3 143842 BAL SATAjet 1000 B indb 508 31 10 2019 13 23 41 ...
Page 509: ... 4 5 6 143842 BAL SATAjet 1000 B indb 509 31 10 2019 13 23 45 ...
Page 510: ... 7 8 143842 BAL SATAjet 1000 B indb 510 31 10 2019 13 23 47 ...
Page 511: ... 9 143842 BAL SATAjet 1000 B indb 511 31 10 2019 13 23 50 ...
Page 512: ...143842 BAL SATAjet 1000 B indb 512 31 10 2019 13 23 50 ...