47
Advanced thermostat settings
To access advanced thermostat settings, turn off the device by briefly pressing the
key. The device must be off or in
standby. Then long press the
P
button (3 seconds) and enter the advanced setting. You can change the values using
or
keys. Press the
P
button to move through the menu and save the settings with the
R
key (exit the settings).
Settings explanation:
Step
Setting
name
(default
value)
Change
option
Description
1
CL (0)
-
4 do +4
Temperature display correction
2
AH (350)
20 –
35 (v
°C)
Maximum output, operating temperature
3
AL (50)
5
–
20 (v
°C)
Lowest output, operating temperature
4
FC (C)
C / F
Temperature display in Celsius or Fahrenheit
5
bL (05)
00 / 05 / 15
Backlight duration in seconds
6
db (05)
0.5
–
3.0
Temperature range: temperature difference between switching on and off.
If, for example, the temperature on the system is set at 22 ° C and the
range at 0.5 ° C the heating system starts to operate if the room
temperature drops to 21.5 ° C and switches off when the temperature
reaches 22.5 ° C.
Settings continue on the next page
Summary of Contents for SAS908XWHB-7-RF