Important safety information

 Always turn off power at the main power source by unscrewing fuse or switching

 circuit breaker to the off position before installing, removing, cleaning, or servicing
 this thermostat.

Read all of the information in this manual before installing this thermostat.

Only a professional contractor should install this thermostat.

All wiring must conform to local and national building and electrical codes and

 ordinances.

Use this thermostat only as described in this manual.

                   

13

14

Summary of Contents for SAS6000UTK-7-WIFI

Page 1: ...info saswell com Factory 3 4 6 F Building A East 8th Region shangxueIndustry Science Park Buji town ShenzhenCity Guangdong China SAS6000UTK 7 WIFI SAS6000UTK 7 WIFI Installation and Operation Instruc...

Page 2: ...stat installation 07 The wiring diagram 08 Alternate wiring conventional system 09 Alternate wiring for heat pumps only 11 Batteries installation 12 Program setting 20 Permanent hold override 24 Vacat...

Page 3: ...s SAS6000UTK 7 WIFI thermostat wallplate attached to back Wire labels Wall anchors and mounting screws 2 each Instruction for Installation and Operation 01 02 SAS6000UTK 7 WIFI Installation Operation...

Page 4: ...wires attached when you remove cover and thermostat 1 Use a screwdriver to disconnect wires one by one As you disconnect each wire wrap it with the label matching the letter on your old thermostat Adh...

Page 5: ...op and bottom of wallplate and pull to remove from thermostat Wallplate Pull wires through wallplate Level wallplate if desired Mark positions of both screw holes 4 Mark wallplate mounting position 1...

Page 6: ...and snap into place The Wiring Diagram Insert wires then tighten screws L RH RC G AUX E S2 S1 Y C O B Y2 L RH RC G W W2 S2 S1 Y C Y2 1 Match each labeled wire with same letter on terminal Use HEAT PU...

Page 7: ...ith electrical tape and do not connect them 1H 1C System RC RH W Y G C W2 Y2 Rc R W Y G C W2 Y2 2 3 2 Remove metal jumper connecting RH and RC only if you must connect both RH and RC wires If your old...

Page 8: ...right and connect to terminal as shown here see notes below 2 3 3 5 5 4 6 6 RH S1 S2 S1 S2 Remote Sensor Remote Sensor Compressor contactor Fan relay 24v common Changeover valve Equipment monitor Eme...

Page 9: ...the o position before installing removing cleaning or servicing this thermostat Read all of the information in this manual before installing this thermostat Only a professional contractor should insta...

Page 10: ...cluding Single stage Multi stage And Heat Pump Up to 3 stage heat 2 stage cool with Aux Or Emergency heat Large LCD display with backlight continuous backlight option Menu driven programming Fan switc...

Page 11: ...ed on the same day When SYSTEM button set to AUTO the thermostat automatically select heating or cooling depending on the indoor temperature 2 Press the to save and exit DONE 17 18 COOL Thermostat con...

Page 12: ...he fan only when the heating or cooling system is on ON Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning 2 Press to enter set program SET SC...

Page 13: ...eturn Home Evening 17 00 WAKE SLEEP LEAVE RETURN 6 Press or to adjust the time for program period start WAKE SLEEP LEAVE RETURN 9 After you have complete the settings press to con rm and exit DONE 8 P...

Page 14: ...ek 1 In Heating lower temperatures will save energy 2 In Cooling higher temperatures will save energy 3 If you plan on using Auto Changeover set the heating temperature below the cooling set temperatu...

Page 15: ...the vacation hold program is completed if you want to resume the schedule earlier please press RUN SCHED This feature can suspend the program schedule for extended period of days RUN SCHED This functi...

Page 16: ...o you can clean the screen without changing any setting 4 After 30 seconds press to DONE resume normal operation or press again if you CLEAN DISPLAY require more time for cleaning CLERN CLEANDISPLAY D...

Page 17: ...enu 4 Press the for display other menu OTHER 5 Press the for entering CONFIG con guration menu 6 Press to select con guration parameter setting 7 Press for changing to NEXT STEP the next menu item set...

Page 18: ...lt 2H This option apply only to HP1 or HP2 setting in system type option 4 Manual Autochangeover option Parameter options 0 1 0 Manual changeover 1 Auto changeover Factory default 0 5 Auto changeover...

Page 19: ...ow set point Factory default FA This option apply only to HP1 or HP2 setting in system type option 10 Compressor lockout delay option Parameter options 0 5 To protect the compressor from short cycling...

Page 20: ...nd stage heating will activate 2 5 below rst stage heating Factory default 7 16 Sceond stage cooling rate option Parameter options FA SL FA Fast second stage cooling rate Second stage cooling will act...

Page 21: ...UF It means cancel the function Factory default UF The thermostat will display the Chg UV when UV time 400 days has expired 21 Heat pump compressor lockout option Parameter options 0 15 20 25 30 35 4...

Page 22: ...e output Cooling is e ective Factory default o 39 40 In case of di culty How to install Please check user instruction on Page 7 How do I open the back cover Grasp top and bottom of wallplate andpull t...

Page 23: ...ting program c check the con guration table and con rm the value of the Item 14 PRGM to be 7 Page 35 in operation manual How do I open the back cover Grasp top and button of wall plate and pull to rem...

Page 24: ...FI frequency 2 4 Ghz or 5Ghz This thermostat only work for 2 4 Ghz Before install adjust your router to 2 4Ghz Insert router name and account get failed The router password should have not special cha...

Reviews: