![Saswell SAS6000UTK-7-WIFI Instructions For Installation And Operation Manual Download Page 18](http://html1.mh-extra.com/html/saswell/sas6000utk-7-wifi/sas6000utk-7-wifi_instructions-for-installation-and-operation-manual_1199950018.webp)
1
.
System type option
Parameter options:(1H,2H,HP1,HP2)
1H: 1 heat/1 cool conventional 2H: 2 heat/2 cool conventional
HP1: 1 compressor heat pump HP2: 2 compressors or 2 speed compressor
heat pump
Factory default:2H
2
.
Fan control option
Parameter options:(HA,HE)
HA: Gas heating. Furnace controls blower
HE: Electric heating. Thermostat controls blower
Factory default:HA
3
.
Auxiliary heat type option
Parameter options:(HA,HE)
HA: Fossil fuel backup heat HE: Electric backup heat
Factory default:2H
This option apply only to HP1 or HP2 setting in system type option
4
.
Manual/Autochangeover option
Parameter options:(0,1)
0: Manual changeover 1: Auto changeover
Factory default:0
5
.
Auto changeover dead band option
Parameter options:(2~9
℉
)
Factory default:3
℉
6
.
Intelligent recovery option
Parameter options:(OF,ON)
OF: Deactivate the intelligent recovery function
ON: Activate the intelligent recovery function
Factory default:OF
1.Intelligent recovery function doesn't activate when program setting to
non-programmable.
2.Intelligent recovery function: it means bringing your room temperature to the set
temperature at exactly the pre-set time by turning on the heating earlier.
31
32