GSD
(Get Shut Down)
: O
utputting TxD data on SD (Shut Down) INFORMATION of
Service Factory MENU
•
The acquired data are output according to the transmission order and size in the table below.
•
This command is valid only in RS-232C Factory Adjustment mode and during shut down (for 30 seconds until a shutdown occurs or standby).
Note:
During power-down, data can be obtained by directly executing "GPD" without executing "FAY." However, the ID must be set
beforehand.
Order
Data Contents
Size
Remarks
1
The latest "SD INFO"
1 byte
(Note 1)
2
First latest "SD INFO"
1 byte
(Note 1)
3
Second latest "SD INFO"
1 byte
(Note 1)
4
Third latest "SD INFO"
1 byte
(Note 1)
5
Fourth latest "SD INFO"
1 byte
(Note 1)
6
Fifth latest "SD INFO"
1 byte
(Note 1)
7
Sixth latest "SD INFO"
1 byte
(Note 1)
8
Seventh latest "SD INFO"
1 byte
(Note 1)
GET Data
Shut Down Point
1
Panel microcomputer communication failure
2
Module IIC communication failure
3
Condensation
4
Temperature abnormality
5
FAN abnormality
6
Module microcomputer communication failure
7
Wide microcomputer communication failure
8
Main IIC communication failure
9
AUDIO failure
(Note 1) See the table below on SD information
Table 1: GSD
Table 2: SD contents
Summary of Contents for AED-5001
Page 11: ...PDP 503CMX 9 5 6 7 8 5 6 7 8 C D F A B E...
Page 161: ...PDP 503CMX 159 5 6 7 8 5 6 7 8 C D F A B E Block Diagram...
Page 162: ...PDP 503CMX 160 1 2 3 4 1 2 3 4 C D F A B E Pin Function 1 3...
Page 163: ...PDP 503CMX 161 5 6 7 8 5 6 7 8 C D F A B E Pin Function 2 3...
Page 164: ...PDP 503CMX 162 1 2 3 4 1 2 3 4 C D F A B E Pin Function 3 3...