Sartorius TopMix TM01-X Installation Instructions Manual Download Page 15

15

C

Marking

The TopMix equipment complies with the
following EC Directives and European
Standards:
Council Directive 89/336/EEC 
“Electromagnetic compatibility (EMC)” 
Applicable European Standards:
Limitation of emissions:
In accordance with product standard EN
61326-1 Class B 
(residential area)
Defined immunity to interference: 
In acc. with product standard EN 61326-1
(industrial area)

Note:
The operator shall be responsible for any
modifications to Sartorius equipment and
must check and, if necessary, correct these
modifications. On request, Sartorius will
provide information on the minimum oper-
ating specifications (in accordance with the
Standards listed above for defined immuni-
ty to interference).
73/23/EEC “Electrical equipment designed
for use within certain voltage limits”
Applicable European Standards:
EN 60950
Safety of information technology equip-
ment including electrical business equip-
ment
EN 61010
Safety requirements for electrical equip-
ment for measurement, control and labora-
tory use
Part 1: General requirements
If you use electrical equipment in installa-
tions and under ambient conditions subject
to higher safety standards, you must com-
ply with the provisions as specified in the
applicable regulations for installation in
your country.

Recycling

The packaging protects the equipment
from damage during transport. After suc-
cessful installation of the equipment, you
should return this packaging for recycling.
For information on recycling options,
including recycling of used equipment,
contact your municipal waste disposal cen-
ter or local recycling depot.

Serial Number Coding

The month and year of manufacture are
encoded in the serial number as follows:
Y M M x x x x x
Y Year
1 2000–2006
2 2007–2013
3 2014–2020
4 2021–2027
5 2028–2034
6 2035–2041
7 2042–2048
8 2049-2055
9 2056-2062

The first digit represents a 7-year period
(see the table above); the next 2 digits rep-
resent the month. Months are numbered
consecutively over the entire 7-year period,
starting at 13. Thus the number represent-
ing the month also indicates the specific
year of manufacture.
2000

13-24

2001

25-26

...

Example:
113xxxxx

January 2000

The individual devices are numbered con-
secutively in the last 5 digits, starting from
00000 again at the beginning of each
month.

Summary of Contents for TopMix TM01-X

Page 1: ...98648 011 50 Installation Instructions Sartorius TopMix Model TM01 X Electronic Paint mixing Weighing System...

Page 2: ...nnector for the power cord power supply 90 to 264 VAC 11 Connector for monitor VGA test monitor 800x600 pixels outside the hazardous area 12 Connector for the VGA video cable YCC01 0039M3 length 3 m C...

Page 3: ...can be connected to the Ex link box YCO09 Z outside the hazardous area Note Read the installation and operating instructions carefully before connecting the TopMix and putting it into operation 2 Gene...

Page 4: ...receive sufficient training to recognize faulty operating states and to introduce the required measures in such cases for example disconnecting the Ex link box from power Legal Notices This equipment...

Page 5: ...s equipment Use only cables and cable lengths approved by Sartorius The operator shall be solely responsible for any damage or injuries that occur when using cables not supplied by Sar torius The Ex l...

Page 6: ...inal TM01 X with LC display and keypad for use in Zone 1 hazardous areas Ex link box YCO09 Z for use outside the haz ardous area TopMix Ex link cable part no YCC01 0038M20 for connecting the terminal...

Page 7: ...g conductor is connected to the housing of the Ex link box All equipment must be connected to the equipotential bonding con ductor by connecting the grounding cable not included in delivery to the gro...

Page 8: ...Before connecting or disconnecting data cables or control lines to or from the device make sure all equipment is disconnected from power The explosion protected paint mixing weighing system must be s...

Page 9: ...length 20 m to the terminal Tighten the connector Connect the TopMix VGA video cable YCC01 0037M20 length 20 m to the terminal Tighten the fastening screws Connect the weighing instrument e g PMA scal...

Page 10: ...fied in national regulations for electrical installa tions Installation must be performed by a trained technician in accordance with national regula tions and acknowledged technological standards The...

Page 11: ...rews USB port see illustration Connect the TopMix PC USB cable YCC01 0040M3 length 3 m for a standard computer to the Ex link box outside the hazardous area PC side Connect the PC video cable YCC01 00...

Page 12: ...dous area PC side Computer setting high color 16 bit Connect the equipment to power PC side Note Observe the warnings and safety precautions included in these instructions Note The Ex link box YCO09 Z...

Page 13: ...ure the currently valid regulations and guidelines for installing equipment in a Zone 1 area in Germany ElexV of 27 Feb 1980 are strictly observed Switching the TopMix On and Off The TopMix terminal T...

Page 14: ...ervice contracts with regular maintenance intervals ranging from 1 month to 2 years The optimum mainte nance interval depends on operating conditions and tolerance requirements Repairs Defective equip...

Page 15: ...f you use electrical equipment in installa tions and under ambient conditions subject to higher safety standards you must com ply with the provisions as specified in the applicable regulations for ins...

Page 16: ...16...

Page 17: ...g 16 5 Ex link box approx kg 3 2 AC power source V 100 240V Frequency Hz 50 60 Power consumption average VA 25 Designation type of explosion protection Terminal TM01 X EEx ib d ib IIB T4 and II 2 G KE...

Page 18: ...Declaration of Conformity 18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...s see note 5 Vmax Imax Ci Li appropriate for connection to associated apparatus with Entity Concept parameters listed above each circuit Vmax 12 6V Voc 12 0V Imax 33mA Isc 32mA Pi 103mW Po 94mW Ci 2 n...

Page 24: ...with Entity Concept parameters listed above 0 1 2 0 SARTORIUS AG 3 4 5 1 2 AC Supply 2 Video in AC DC 4 1 2 Video out 2 USB SARTORIUS AG 3 83 9 699 3 83 9 699 3 83 9 699 3 83 699 Cable 8 Type YCC01 00...

Page 25: ...ters 6 7 range 0 40 7 WARNING SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY 8 Maximum cable length 100m 328 ft 1 For installation Not for esters and alkanes atmospheres For 1 installation No...

Page 26: ...without the prior written permission of Sartorius AG The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius AG reserves the right...

Reviews: