![Sartorius IF CE Series Installation And Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/sartorius/if-ce-series/if-ce-series_installation-and-operating-instructions-manual_1199740006.webp)
Affixing Equipment Designation Labels to the IF...CE
Equipment designation labels that correspond to configuration
of the scale must be affixed to the equipment prior to initial
verification. To do this, affix the labels to the display and con-
trol unit/indicator or, in special cases, to the plates provided. If
plates are required, they are included in the equipment supplied
with the display and control unit/indicator. Fasten the plate to
the connecting cable between the IF...CE and the display and
control unit/indicator and affix the label to the plate.
Connecting the Flat-bed Scale to Power
The flat-bed scale is powered over the cable that connects the
display and controle unit/indicator.
Unpacking the Equipment
§
Please read the enclosed operating
instructions carefully before putting
the equipment into operation.
§
After unpacking the equipment,
please check it immediately for any
visible damage.
§
Open the wooden pallet at the top.
$
Lift the scale until it is completely
free of the wooden pallet
(see below).
Note:
The height of the load-bearing
feet can be adjusted. The scale
is adjusted at the factory for
a level floor. Improper handling
of the scale can result in damage to
the components, which negatively
affects the safety of the device.
Make sure to read and follow the
safety instructions.
§
Fasten the straps in four places,
as shown here:
– Front: handles
– Rear: carrier frame.
§
Lift the scale evenly.
§
Move the scale to the place of instal-
lation.
!
Warning: Danger of personal injury!
Do not stand or move beneath the
scale while it is suspended.
Make sure to read and follow the
safety instructions.
§
Lower the scale evenly to the place
of installation.
$
The place of installation must be
clean, level and able to withstand the
weight of the scale and any load that
will be placed on it. Eliminate any
unevenness of the floor surface
( character skew < 5cm ).
§
Level the scale at the place of instal-
lation using the level indicator. Check
the angularity of the base frame and
make sure it is correct. Measure the
diagonals to check this dimension.
§
Mark the positions for drilling
anchor holes.
– 8 fastening anchors, sizes M10
to M15 (length: 85 mm),
are included in delivery
§
Clear the place of installation.
Lift the scale evenly.
!
Warning: Danger of personal injury!
Do not stand or move beneath the
scale while it is suspended.
Make sure to read and follow the
safety instructions.
§
Drill the holes (size: M10) for the
anchors. Minimum depth: 65 mm.
§
Check the depth; remove all dust
from the bore hole (use a blower if
necessary).
§
Clean the place of installation.
§
Carefully re-position the scale at the
place of installation. Make sure to
align the holes drilled for the anchors
with the bore holes on the base frame.
§
Level the scale at the place of instal-
lation using the level indicator. Check
the angularity of the base frame and
make sure it is correct. Measure the
diagonals to check this dimension.
§
Fasten the scale as follows:
Drive in the anchors and tighten the
bolts (size M10; wrench size: 17).
5