background image

15

Declarations of Conformity

The 

C

 marking may be affixed only  

to equipment that complies with the  

following Directives (below). Conformity 

has been tested in conjunction with  

Sartorius equipment:

Council Directive 89/336/EEC  

“Electromagnetic compatibility (EMC)” 

as amended by 93/68/EEC

Applicable European Standards:

  1.1   Reference to 89/336/EEC:  

Official Journal of the European 

Communities, No. 2001/C105/03 

 

EN 61326-1 

 Electrical equip-

ment for meas-

urement, control 

and laboratory 

use EMC require-

ments 

   

Part 1: 

 General requirements  

Defined immunity  

to interference: 

Industrial areas, conti-

nuous, un-monitored 

operation  

Limitation of emis-

sions: 

Residential areas,

   

IF.... 

Class A

Note:

The operator shall be responsible for  

any modifications to the indicator and 

for any connections of cables or equip-

ment not supplied by Sartorius.  

On request, Sartorius will provide  

information on the minimum operat-

ing specifications (in accordance with 

the Standards listed above for defined 

immunity to interference).

73/23/EEC “Electrical equipment 

designed for use within certain voltage 

limits” as amended by 93/68/EEC

Applicable European Standards:

EN 60950   Safety of information  

technology equipment 

including electrical business 

equipment 

EN 61010   Safety requirements for 

electrical equipment for 

measurement, control  

and laboratory use 

Part 1: 

General requirements 

“EC Verification” –  

A Service Offered by Sartorius

Our service technicians authorized to 

perform the verification of your weigh-

ing instruments that are acceptable  

for legal metrological verification can 

inspect and verify the metrological 

specifications at the place of installa-

tion within the Member States of the 

European Union and the Signatories  

of the Agreement on the European  

Economic Area.

Subsequent Verifications within the 

European Countries

The validity of the verification will 

become void in accordance with the 

national regulations of the country in 

which the weighing instrument is used. 

For information on verification and 

legal regulations currently applicable in 

your country, and to obtain the names 

of the persons to contact, please con-

tact your local Sartorius office, dealer  

or service center.

Summary of Contents for IF CE Series

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...Installation and Operating Instructions Sartorius IF Standard and IF CE with T8 Lifting Mechanism Flat bed Scale 98648 012 37 98648 012 37...

Page 3: ...arf die W gebr cken mit klappbarer Last platte ffnen schlie en Sicherstellen dass sich keine Personen im Gefahrenbereich vor oder un ter der aufgeklappten Lastplatte befinden Bedienung nur von der rec...

Page 4: ...fac turer s warranty If the equipment housing is opened by anyone other than per sons authorized by Sartorius this will negate its con for mity with regulations governing its use and result in forfeit...

Page 5: ...Make sure there are no cables or other objects exerting force on the load plate Avoid generating static electricity Using the IF CE in Legal Metrology in the EU The type approval certificate for veri...

Page 6: ...t the scale evenly Move the scale to the place of instal lation Warning Danger of personal injury Do not stand or move beneath the scale while it is suspended Make sure to read and follow the safety i...

Page 7: ...s slide into the side plate and secure the platform in the vertical position The surface under the platform can now be cleaned easily Install the pneumatic springs right and left as shown in the illus...

Page 8: ...the two hand cranks to the two threaded fasteners at the front of the scale Turn the cranks clockwise to lower the transport rollers Repeat this procedure for the two rear rollers Important Make sure...

Page 9: ...e sleeve and the side plate Screw the left base plate 7 and the left side plate 1 together and the right base plate 8 and right side plate 2 together using screw M12 65 and nut M12 Place the lift up m...

Page 10: ...platform so that the back load bearing feet are in the fastening plates of the transverse strut and align Screw the four downholders 9 to the side plates 1 and 2 using M6 20 The platform and the downh...

Page 11: ...plastic impact cap 19 to protect the flooring When lifting up and down for the first time ensure that the measurement cable is not damaged or squashed Mount the grips to the scale platform Drill holes...

Page 12: ...voltage black brown blue Signal Output signal white green Signal Output signal red pink gray Sense Sense line green white Sense Sense line gray black Ground Shield Shield Shield Diagram Showing Loadi...

Page 13: ...pacities 59 models 3000 e 2 3000 e Cl III depends on model 15 000 d 30 000 d Material surface finishing AISI 304 or AISI 316 Ti stainless steel brushed or electropolished IP67 IP65 rating Stainless st...

Page 14: ...F is no longer war ranted i e If there is visible damage to the connecting cable If the device no longer functions properly If the equipment has been stored for a relatively long period under unfa vor...

Page 15: ...m to the floor Floor mounting set YFP01I Columns can be manufactured to order on request Dimensions Designation GG IG II LG LI LL NL NN RN RR WR D mm 600 800 800 1 000 1 000 1 000 1 250 1 250 1 500 1...

Page 16: ...interference 73 23 EEC Electrical equipment designed for use within certain voltage limits as amended by 93 68 EEC Applicable European Standards EN 60950 Safety of information technology equipment inc...

Page 17: ...16...

Page 18: ...17...

Page 19: ...18...

Page 20: ...19...

Page 21: ...20...

Page 22: ...21...

Page 23: ...22...

Page 24: ...23...

Page 25: ...24...

Page 26: ...25...

Page 27: ...26...

Page 28: ...27...

Page 29: ...he prior writ ten permission of Sartorius All rights reserved The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius reserves the...

Reviews: