Inside of door
Fig. 7A
PERSONA
PG controller
DIP switch location
Mortise Installation Instructions (Continued)
1. Place (6) “AA” batteries into the compartment, being careful to properly align polarity (- & +) .
2. Insert battery pack and click into place making sure polarity terminals on the battery pack are oriented upward
as in Fig. 7A.
3. Verify DIP switch settings are correct for the application.
PERSONA PG Controller DIP Switch Settings
(Fig 7A):
SARGENT mortise lock with
and without deadbolt:
• Switch 1 and 2 - OFF
• Switch 3 - ON
SARGENT cylinder or exit locks:
• Switch 1 - OFF
• Switch 2 and 3 - ON
1. Position inside escutcheon (Fig. 8A); insert screws top and bottom
and tighten securely. Do not over tighten.
Note: All wires should be placed inside to avoid being pinched.
2. Straighten escutcheon and tighten securely.
Battery pack
Fig. 8A
(2) #8-32 x
1/2” pan head
security torx
machine screws
Inside of door
7 - Battery/Battery Pack Installation and
DIP Switch Verification
8 - Installation of Inside Escutcheon
20
A7809B
Copyright © 2012, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
10/31/12
Passport 1000 PG Exit Device
ON
OFF
ON
OFF