background image

Document 630-881

Revised 09/17/2021 

Copyright

©

 2021, Sargent & Greenleaf

5/7

Temporarily attach panic bar assembly to interior mounting plate 

using (2) #10-32 x 1/2" screws.

Slide panic bar touch pad back into panic bar channel, insert panic bar channel bracket and 

filler panel into panic bar channel.

58

Level panic bar assembly.

61

Secure strike with (3) 

remaining #10 sheet metal 

screws or #10-32 machine 

screws, tighten securely.  If 

machine screws are used, 

threadlocker is recom-

mended.

A

4

52

Slide panic bar touch pad partially from panic bar channel.

W

55

F

Adjust trip mechanism to engage 

strike.  Slowly close door, observe whether 

the bolt is released upon closing.  If bolt is 

not released, use a flat blade screwdriver 

and rotate the trip mechanism counter 

clockwise 1/2 turn.  Repeat adjustment 

until bolt is extended upon door closing 

and rotate trip mechanism 1 additional full 

turn counter clockwise.

Test all door and lock functions for 

proper operation.  Make necessary 

adjustments if required.

53

54

To access High Security Combina-

tion Lock:  Unlock center module 

and upper module with key, 

remove (6) interior module cover 

assembly screws and (2) lock 

cover screws.  Time to preform 

this operation is 1 min 10 sec.  

Reverse process to re-install 

covers.  Refer to High Security 

Combination Lock - Operating 

Instructions for detailed instruc-

tion, including how to change lock 

combination.

W

X

Y

Align panic bar assembly to lock assembly.

59

Align panic interface mechanism to panic bar touch pad.

From backside of panic bar touch pad, secure panic 

interface mechanism with (2) #8-32 x 3/8" screws.

W

1

W

W

2

W

2

W

1

W

56

57

W

3

W

3

60

Summary of Contents for 2890C

Page 1: ... x 1 Phillips Pan Head Machine Screw Qty 4 Bolt Extension Qty 1 10 32NF x 1 Phillips Flat Head Machine Screw Qty 2 10 32 x 1 4 Phillips Pan Head Machine Screw Qty 2 F2 L L1 Q2 Tools Recommended A B F G K L N P Q R S T U V W X Y R1 A1 4x B1 4x B2 4x A3 4x A4 6x F1 4x F1 2x F1 2x A4 5x E H J A4 2x E1 2x Q1 F1 4x Q3 4x Q2 2x V1 4x A4 2x Z1 2x X1 2x Optional 2890C SCIF Lock Panic Exit Device A4 2x F2 ...

Page 2: ...ior mount ing plate assembly to the through holes on door exterior Position exterior mounting plate assembly flush against exterior side of door A 4 Heavy gage metal doors may require tapped holes and machine C 14 16 D Install the rim cylinder or plug through the exterior escutcheon C A Slip the exterior escutcheon around the handle and position over the exterior mounting plate assembly 15 A4 A Ins...

Page 3: ...th of mounting screws Locate the previously removed access control assembly and position it with the vertical side of the access bolt facing the door hinge Install access control cover Center punch mounting holes 4x using housing holes as guide 23 24 25 A4 A4 E E E1 26 27 28 29 30 31 F1 Position lock housing above mechanical assembly and access control housing below mechanical assembly Flip the co...

Page 4: ... previously installed screws 50 Retract bolt open door and realign strike to reference lines on frame Center punch top left slotted strike mounting hole 1x 42 Mark strike position reference lines on frame 41 43 Pre Drill for 10 sheet metal screw or drill tap for 10 32 machine screw Spacers are used to adjust clearance between the strike lock and are not required for every Align strike spacers and ...

Page 5: ...ewdriver and rotate the trip mechanism counter clockwise 1 2 turn Repeat adjustment until bolt is extended upon door closing and rotate trip mechanism 1 additional full turn counter clockwise Test all door and lock functions for proper operation Make necessary adjustments if required 53 54 To access High Security Combina tion Lock Unlock center module and upper module with key remove 6 interior mo...

Page 6: ...interior center cover assembly to mechanical assembly V Q U V Q V Q T U Q T V1 Q2 Q3 Z Z1 S1 66 Insert short spindle 67 70 71 Install endcap 72 Install interior center cover assembly Ensure that the exit module engages the spindle and panic mechanism Secure with 2 10 32 x 1 4 pan head screws and 3 10 32 x 1 4 flathead screws Align panic mechanism to panic mechanism shim Secure panic mechanism shim ...

Page 7: ...s para ajustarse a su aplicación Para mejorar la seguridad y reducer riesgos usted debe consultar con un cerrajero especializado u otro profesional de seguridad Pour de l aide ou des informations sur la garantie Vauillez appeler le 1 859 885 9411 ou visiter www sargentandgreenleaf com Advertissement Le fabricant tient à vous aviser qu aucun verrou ne peut à lui seul offrir une sécurité complète Ce...