background image

31

The Sapling Company, Inc.
1633 Republic Road
Huntingdon Valley, PA 19006
USA

(+1) 215.322.6063 P.
(+1) 215.322.8498 F.
www.sapling-inc.com

Web Interface Programming

Synchronization

1.

 

Input Selection

  This drop-down list allows the user to select which input will control the master clock.  The choices are: 

• 

Real Time Clock

• 

58 Minute Sync_1

• 

National Time_Rauland 

• 

Wireless Repeater

• 

GPS

• 

58 Minute Sync_2

• 

Dukane Digital

• 

RS485

• 

NTP

• 

58 Minute Sync_3

• 

Rauland Digital

• 

59 Minute Sync

• 

58 Minute Sync_4

• 

Once a Day Pulse

If Once a Day Pulse is selected, then fields for hours, minutes and seconds will appear.  Enter the time (in 24 hour mode) that the clock is to 

go to when a once a day pulse is present.  It must be a minimum of a one second pulse.

2.

 

Backup Selection

  This drop-down list allows the user to select a backup input in case of the loss of the primary input.  In order to use 

the Backup Selection, the following protocols cannot be used as both a primary and secondary input:  59 minute sync, 58 minute 1-4 sync, 
National Time/Rauland, Dukane Digital, Rauland Digital and once a day Pulse.  An example of a configuration would be NTP being the 
primary input and 58 minute correction being a secondary input.   Setting the primary source to 59 minute sync and the secondary source to 
Dukane digital would be an incorrect configuration.

3.

 

Clock #1 Circuit

  This drop-down list allows the user to select the sync-wire output for the Clock #1 circuit.  The choices are:

• 

59 Minute Sync*

• 

58 Minute Sync_3*

• 

National Time_Rauland  2*

• 

58 Minute Sync_1*

• 

58 Minute Sync_4*

• 

Once a Day Pulse

• 

58 Minute Sync_2*

• 

National Time_Rauland_1*

• 

Rauland Digital

4.

 

Clock #2 Circuit

  This drop-down list allows the user to select the sync-wire output for the Clock #2 circuit.  See #3 above for the list of 

choices.

5.

 

Submit

  This button, when pressed, will save all of the information to the master clock.

6.

 

Cancel

  This button, when pressed, will clear out any changes made and will not save any data.

 

NOTE:  GPS is only valid if the option is purchased.

* See page 24 for protocol definitions

q

e

w

r

t

y

Summary of Contents for NTP 7000 Series

Page 1: ...NTP 7000 Series Master Clock The Sapling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Installation Manual V1 ...

Page 2: ...ion System Connection 11 Once a day Pulse Using Clock 1 or Clock 2 System Connection 12 59 Minute Correction 13 58 Minute Corrections 1 4 13 National Time Rauland 14 Rauland Digital 14 Dukane Digital 15 Once a Day Pulse 15 Fire Alarm Interface Installation 16 Patch Cable Installation 16 GPS Antenna Installation 17 Setting Master Clock to GPS Mode 17 Setting the Time from the LED Display 18 Program...

Page 3: ...y PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Table of Contents IP 32 NTP Servers 33 IP Status 34 Clock Features 35 Database Maintenance 36 Support Frequently Asked Questions 37 Troubleshooting 38 Compliances 39 NTP 7000 Series Master Clock ...

Page 4: ...ng the template from the top right hole 4 Using a level and the LINE on the supplied template mark the center of the three remaining holes 5 Remove the template and drill out the three remaining holes and insert the anchors 6 Insert the two top screws into the anchors leaving 1 8 of thread exposed Unscrew the bottom wiring cover on the master clock 7 Line up the top keyholes on the back of the mas...

Page 5: ... 8498 F www sapling inc com 1 The master clock is 1U in size Install the threaded nuts in the desired location in the rack rails 2 Put the nylon washers on the two screws supplied 3 Line up the master clock with the threaded nut 4 Insert screws into the threaded nuts and tighten Rack Mount Installation ...

Page 6: ...he insulation on the White and Black wire 6 Put each wire into the supplied connector and tighten the screws The wiring label located on the wiring chassis indicates where to connect the wires Caution Do not plug in the power cord until the following steps are completed 1 The square knockout on the wiring chassis must be removed 2 The Heyco Bushing must be attached to the power cord as shown Use p...

Page 7: ...eping capabilities 6 GPS Connector This GPS connector is where the antenna for the GPS gets mounted to GPS option only 7 Power Input This power outlet is used to power up the NTP master clock NOTE This device contains a lithium battery Replace Battery With Varta Part No CR2032 Only Use Of Another Battery May Present A Risk Of Fire Or Explosion Batteries can be obtained and should be installed by t...

Page 8: ...upplied in the mounting kit at the designated markings from step 1 4 Install the four anchors in the holes that were just drilled 5 Install the first two screws in the top holes leaving 1 8 of the thread exposed 6 Line up the top key slots over the screws and lock the master clock into place 7 Install the bottom screws through the wiring access panel and tighten into place 8 After all wiring is co...

Page 9: ...lic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com System Connections Wired Systems 2 Wire Digital Communication System Connection 110V EU 240V 110V EU 240V 18 19 24V SBD 3000 Series Wired Clock ...

Page 10: ...6 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com System Connections Wired Systems RS485 Communication System Connection EU 240 24VAC 110 24V SBD 3200 3300 Series Wired Clock EU 240 24VAC EU 240 24VAC EU 240 24VAC Black White Black Yellow Orange White Black White ...

Page 11: ...Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com System Connections Wired Systems Sync Wire Communication System Connection SBD 3300 Series Wired Clock EU 240 24V EU 240 24V EU 240 24V EU 240 24V Yellow Blue Black Yellow White Orange ...

Page 12: ... Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com System Connections Wired Systems Once a day Pulse Using Clock 1 or Clock 2 System Connection Intercom paging system or other device Clock Circuit 24 23 or 27 28 ...

Page 13: ...nputs Installation 59 Minute Correction 58 Minute Corrections 1 4 Dry Contact Closure Dry Contact Closure N O 110VAC Neutral 24VAC Neutral 110VAC Neutral 24VAC Neutral N O COM 110VAC Hot 24VAC Hot 110VAC Hot 24VAC Hot COM 110VAC Interface 110VAC Interface 24VAC Interface 24VAC Interface 7 7 16 16 15 15 8 8 17 17 17 17 17 17 12 12 EU 240VAC EU 240VAC ...

Page 14: ...ling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Inputs Sync Wire Inputs Installation National Time Rauland Rauland Digital Dry Contact Closure 110VAC Interface 24VAC Interface EU 240VAC ...

Page 15: ...pling Company Inc 1633 Republic Road Huntingdon Valley PA 19006 USA 1 215 322 6063 P 1 215 322 8498 F www sapling inc com Inputs Sync Wire Inputs Installation Dukane Digital Once a Day Pulse Dry Contact Closure ...

Page 16: ...P server that allows the user to interface the existing fire alarm with the Sapling SBD 3000 series digital clocks Patch Cable Installation N O COM 7 8 10 9 When a relay closure occurs on pins 8 and 9 FirE will display on the digital slave clocks connected using RS485 or two wire digital communication 1 Connect a patch cable to the RJ45 port on the NTP server as shown in Fig 1 1 2 Connect the othe...

Page 17: ...80 degrees view of the sky 2 Run cabling through piping and attach the end of the cabling to the bottom of the GPS dome via TNC connection 3 Screw GPS dome onto the top of the piping Be careful not to twist the cable Use teflon tape on the pipe threads to tighten seal and prevent water damage 4 Mount piping to the roof of the building with mounting plate and hardwear supplied by the user 5 Connect...

Page 18: ...e the hour and or the bottom button the set the minute See Fig 2 1 Programming the NTP 7000 Server To enter programming mode press both the top and bottom button together simultaneously The top button advances through the options while the bottom button changes the option Fig 2 1 Option 1 Set Year Use the bottom button to scroll from 10 99 on the display and set the year Option 2 Set Month Use the...

Page 19: ...tom button to scroll between 01 12 01 Data is transmitted every second 07 Data is transmitted every 2 minutes 02 Data is transmitted every 5 seconds 08 Data is transmitted every 5 minutes 03 Data is transmitted every 10 seconds 09 Data is transmitted every 10 minutes 04 Data is transmitted every 15 seconds 10 Data is transmitted every 15 minutes 05 Data is transmitted every 30 seconds 11 Data is t...

Page 20: ... once a day pulse Press the bottom button to scroll through 00 23 Option 22 Once a Day Pulse Set Minutes This option is only available if 8 is selected in option 20 for once a day pulse Press the bottom button to scroll through 00 59 Option 23 Once a Day Pulse Set Seconds This option is only available if 8 is selected in option 20 for once a day pulse Press the bottom button to scroll through 00 5...

Page 21: ... once a day pulse Press the bottom button to scroll through 00 23 Option 27 Once a Day Pulse Set Minutes This option is only available if 8 is selected in option 25 for once a day pulse Press the bottom button to scroll through 00 59 Option 28 Once a Day Pulse Set Seconds This option is only available if 8 is selected in option 25 for once a day pulse Press the bottom button to scroll through 00 5...

Page 22: ...o scroll through 00 23 00 Real Time Clock 08 Dukane 01 SNTP 09 Rauland Digital 02 59 Minute Correction 10 Wireless Repeater 03 58 Minute Correction 1 11 Once a Day Pulse 04 58 Minute Correction 2 12 GPS 05 58 Minute Correction 3 13 RS485 06 58 Minute Correction 4 07 National Time Rauland Selecting this allows access to options 34 36 Option 32 Setting the Time Zone Offset Press the bottom button to...

Page 23: ...ill appear on the right side if the master is receiving an Inter net Connection A 00 will appear on the right side if it is not receiv ing an Internet Connection This option is a read only option Option 45 Crossover Static IP option If the right side says off DHCP is being used if the user presses the bottom button the display will change to cr which means crossover mode In cross over mode DHCP is...

Page 24: ...rom XX 58 00 to XX 59 00 The daily correction 5 a m 5 p m is twelve correction cycles sent to the relay each for 65 seconds on and 25 seconds off beginning at 5 05 00 to 5 22 35 3 58th minute 3 The hourly correction for 60 seconds every hour from XX 58 00 to XX 59 00 The daily correction 5 a m 5 p m is twelve correction cycles sent to the relay each for one minute on and two minutes off beginning ...

Page 25: ...D Display PM active Ethernet disconnected GPS error DHCP error SNTP error unused __________ _________ ______ _____ ___ _ When one of the following errors occurs one of the LED lights located above one of the six characters on the LED display will being to flash See figure below indicating the error each flashing light is associated with Error Codes ...

Page 26: ...lorer or FireFox on a PC that s connected to the network 4 In the address bar type in 192 168 0 123 and press Enter This will access the log in screen 5 Once you are logged in follow the instructions on page 32 for entering a new IP address Accessing the Web Interface when using a crossover cable 1 Set option 45 to cr as described on page 23 2 If you are accessing this on a laptop turn off any wir...

Page 27: ...nts and schedule changes The default password for the user level is 1111 It can be changed in the technician level The technician level password is 6063 and gives you full access to all of the enabled features of the master clock 2 Log In This button when pressed will attempt to log in to the master clock with the password that was entered in the field above 3 Forgot Password This button when pres...

Page 28: ... hour format HH MM SS After typing in the desired time click the Submit button to set the time on the unit if there is no input connected 2 Date This field is where the current date is displayed The date can be edited by clicking within the field and typing in the desired date The date must be entered in mm dd yyyy format After typing in the desired time click the Submit button to set the date on ...

Page 29: ...nds off plus or minus the time will be when receiving an input This field can range between 0 9999 seconds 4 GMT Offset This field sets the positive or negative offset for GMT time For instance eastern time zone is a negative five hour offset See Fig 4 1 for typical offsets Time in Greenwich Local Time Positive Offset Negative Offset Philadelphia 12 00 p m 7 00 a m 0 5 Eastern Standard Time Noon C...

Page 30: ...d States Day of Month When this option is selected Daylight Saving Time can be chosen based on what date and time it begins and ends i e Daylight Saving Time can begin on March 28 at 2AM and end on November 1st at 2AM Day of Week in Month When this option is selected Daylight Saving Time can be chosen based on what week in what month and what time it begins and ends i e Daylight Saving Time can be...

Page 31: ... be used as both a primary and secondary input 59 minute sync 58 minute 1 4 sync National Time Rauland Dukane Digital Rauland Digital and once a day Pulse An example of a configuration would be NTP being the primary input and 58 minute correction being a secondary input Setting the primary source to 59 minute sync and the secondary source to Dukane digital would be an incorrect configuration 3 Clo...

Page 32: ...however some modification may be needed for certain networks 5 DHCP This drop down list allows the user to turn DHCP on or off DHCP allows the master clock to look for an IP address on its own if the network has a DHCP server 6 Send Status to Monitor on Specified IP This setting allows the clock to send out its data in broadcast mode 7 Monitor IP Address This setting allows for the Monitor IP Addr...

Page 33: ...he user to specify which NTP servers that the master clock will try to acquire time from Any server that is highlighted in red is not functioning after several tries 3 Rotate Servers This checkbox when checked allows the master clock to rotate through all the server addresses for constant time accuracy on a continual basis There must be two server addresses for this option to work 4 Submit This bu...

Page 34: ...address for the master clock 3 Board Serial Number The displays the serial number of the board inside master clock 4 Unit Build Date This displays the date the unit was built 5 Code Build Date This displays the date the software code was built 6 SVN Revision This displays the software version number 7 Device Name This displays the device name for the master clock 8 Paid Provisioned Features This d...

Page 35: ...gramming Clock Features 1 Display Format This drop down list allows the user to select whether they want 12 hour or 24 hour mode to be displayed on the LCD and LED 2 Submit This button when pressed will save all of the information to the master clock 3 Cancel This button when pressed will clear out any changes made and will not save any data q w e ...

Page 36: ... button when pressed will upload the configuration of the master clock and place it in a file for backup purposes 2 Browse File This button when pressed will allow the user to browse for the saved db file that contains the saved events and schedules 3 Download This button when pressed will download the selected file and reset the master clock with those events and schedules already configured q w ...

Page 37: ...nternet Explorer Mozilla Firefox Safari Opera and Chrome Can I connect to the web browser through a cross over cable Yes the NTP master clock can be accessed through a cross over cable or via a LAN connection What are the length options I have with the GPS cable When the GPS option is purchased a 75 foot cable comes standard with the unit An optional 150 foot cable may be purchased Is there a Conv...

Page 38: ...a signal Check the antenna to make sure it is in an unobstructed area that is in complete view of the sky Also check to make sure the connections on each end of the cable are securely tightened Lastly verify that there are no kinks or breaks in the supplied GPS cable My sync wire system doesn t seem to be getting the correct time What should I do The clock 1 and clock 2 outputs control the sync wi...

Page 39: ...paration between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Compliances FCC Statement Information to the user for U S only IC Statement for Canada only This Class B digital apparatus complies with Canadian ICES 003 CET appareil numérique de ...

Reviews: