Electrical Specifications
Please refer to Table 1 for Electrical Specifications.
Parameter
Value
Input Power Supply and Outputs
•
D: Universal Power Supply 18 - 55V DC, 90 - 265V
AC, Single-point two potential free relay outputs rated
at 6A
•
SPN: Universal Power Supply 18 - 55V DC, 90 - 265V
AC
- Singe-point Single relay (Rated 6A)
- Open-collector PNP output, max 100mA
non-inductive load
•
MA1: 24V DC 8/16mA 2-wire Loop powered current
output
•
NMR: 8.2V Namur type current output (I ON = 2.2 to
2.5 mA, I OF F = 0.8 to 1.0 mA)
Namur compliance can be attained with a Namur
certified isolator.
Power Consumption
4W at 24V DC with 90 mA load
Fail-safe Settings
User selectable (Field selectable through toggle switch)
•
Open: Fail-safe High
•
Close: Fail-safe Low
Time Delay Settings
Cover and Uncover Delay: 0.8s / 1s to 20s, through toggle
switches
Sensitivity Setting
Field Selectable (through toggle switches)
Protection
If required, additional over-current and short-circuit protec-
tions can be provided with the use of an external fuse rated
for 500mA.
Table 1: Electrical Specifications
7
Application Specifications
Please refer to Table 2 for Application Specifications.
Parameter
Value
Response Time
•
Cover Delay - 0.8 seconds
•
Uncover Delay - 1 seconds
Hysteresis
3 - 4 mm
Density
Above 0.7gm/
cm
3
Viscosity
Suitable for liquids with viscosity up to 10,000 cP
Table 2: Application Specifications