- 63 -
Service Adjustment
Group/Item
Item Name
Function
Initial
Range Note
Group 250
FAN Cntorol
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
42
0 - 255
1 FAN1 MAX ADJUST (DAC)
234
0 - 255
2 FAN2 MIN ADJUST (DAC)
42
0 - 255
3 FAN2 MAX ADJUST (DAC)
234
0 - 255
4 FAN3 MIN ADJUST (DAC)
42
0 - 255
5 FAN3 MAX ADJUST (DAC)
234
0 - 255
6 Not used
9999 (Dummy)
7 Not used
9999 (Dummy)
Group 251
Not used
Group 252
Fan Option
0 HI-LAND SWITCH
0: Off, 1: Hi-Land 2: Hi-Land max
0
0 - 2
0 (Read Only)
1 SAFETY SWITCH
For test purpose
0
0 - 6
2 FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual
switch is 1
130
0 - 255
4 FAN2 MANUAL VOLTAGE
130
0 - 255
5 FAN3 MANUAL VOLTAGE
130
0 - 255
6 Not used
7 Stand Mode
Stand mode setting
0: Normal(Free) 1: Normal(Fixed)
2: Celling 3: Down 4: Up
0
0 - 4
8 Fan Offset Voltage Update In-
terval
filter clogged Fan Voltage Update
interval time ( sec.)
60
1 - 600
Group 253
Fan Tem Error Setting (Memorized)
Normal Ceiling
Down
Up
0 Not used
1 Not used
2 Not used
3 Not used
4 Not used
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
44
33
44
33
44
33
44
33
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
56
50
56
50
56
50
56
50
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
73
68
73
68
73
68
73
68
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
44
33
44
33
44
33
44
33
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
56
49
56
49
56
49
56
49
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
74
67
74
67
74
67
74
67
30-100 Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Eco (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Eco (Clogging Det.)
100
100
100
100
100
100
100
100
0-100
Normal/Celling/Down/Up
HiLand : Normal/ Celling/Down/Up
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased X°C at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
16 Temp B Warning Offset (Temp)
5
17 Temp C Warning Offset (Temp)
5
18 Temp B-A Warning Offset (Temp)
0
19 Temp C-A Warning Offset (Temp)
0
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
1
21 Temp B Warning Offset (Time)
1
22 Temp C Warning Offset (Time)
1
23 Temp B-A Warning Offset (Time)
1
24 Temp C-A Warning Offset (Time)
1
25 Factory Mode
For factor use
0
Summary of Contents for XGA ULTRA SHORT-THROW PLC-XL51
Page 86: ... 86 IC Block Diagrams BA7078 Sync Separator IC5301 AN5870 Signal Switch IC5201 ...
Page 87: ... 87 FA5502 P F Control IC601 HIN202EIB RS 232C Driver IC3801 IC Block disgrams ...
Page 88: ... M62334 DAC For Fan Control IC3501 PW190 Scaler IC301 88 IC Block disgrams ...
Page 89: ... NJW1141 Audio Control IC5001 89 IC Block disgrams STR Z2156 Power OSC IC651 ...
Page 122: ... 122 Integrator Lens In L10 L03 Optical Parts Layout S7 S7 S7 S7 Relay Lens out ...
Page 123: ... 123 L04 L14 L05 L12 L15 L16 L09 L13 L13 L08 L06 L07 Optical Parts Layout Optical unit inside ...
Page 125: ... 125 ...
Page 126: ...SM5110989 00 PLC XL51 Sep 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...
Page 138: ...A12 SCH_KV7A NO DATA ...