– 19 –
AF_MID1: ZM1
ZM1: adjustment value of focus at zoom position middle1
(–76<=ZM1<=48)
AF_MID2: ZM2
ZM2: adjustment value of focus at zoom position middle2
(–104<=ZM2<=57)
AF_MID3: ZM3
ZM3: adjustment value of focus at zoom position middle3
(–97<=ZM3<=76)
AF_TELE: ZT
ZT: adjustment value of focus at zoom position tele
(–98<=ZT<=94)
2. AWB Adjustment
Adjusting method:
1. When setting the camera in place, set it to an angle so that
nothing appears in any part of the color viewer except the
white section. (Do not enter any light.)
2. Double-click on the DscCalDi.exe.
3. Click the AWB, and click the Yes.
4. AWB adjustment value will appear on the screen.
(When the mecha shutter is failed, “MS=NG:X” will display.)
5. Click the OK.
Adjustment value determination is effectuated using the "AGC",
“CHECK" and "MS" values.
If AGC=a1, a2, a3, a4, a5, CHECK=wc0, wc1, wc2 and
MS=ms1, ms2, the adjustment values fulfill the conditions be-
low, they are determined as within specifications.
Adjustment value determination
100<a1<300, 250<a2<500, 450<a3<650,
550<a4<850, 750<a5<1023
wc0=128
±
2, wc1=128
±
2, 110<=wc2<=200
3400<=ms1<=5300, 3450<=ms2<=5350
Adjustment values other than the above are irrelevant.
3. CCD White Point Defect Detect Adjustment
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
Camera
Pattern box
(color viewer)
Dsc Calibration
x
OK
AWB Results:
1:
AGC=192,362,527,697,866
3F_AGC=1,1
WB=278,514,591
CHECK=128,128,144
MS=4600, 4708
0
IRIS=0
Fno_FOR_ISO=44
SS_FOR_ISO=907
YLEVEL_FOR_ISO=9074
Copy