3-7. Adjust Specifications
1. Lens Adjustment
Preparation:
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the Focus, and click the Yes.
5. Lens adjustment value will appear on the screen.
(When the zoom adjustment is failed, “NG: PZ X” will dis-
play.)
(When the focus adjustment is failed, “NG: AF Y” will dis-
play.)
6. Click the OK.
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
PZ_SW: PSW
PSW: adjustment value of zoom PR switch position
(945<=PSW + PBR<=1010)
PZ_BR: PBR
PBR: adjustment value of zoom backrush pulse
(0<=PBR<=45)
PZ_SP: PSP
PSP: adjustment value of zoom stowing pulse
(210<=PSP<=320)
AF_SW: ASW
ASW: adjustment value of focus PI switch position
(893<=ASW<=985)
AF_BR: ABR
ABR: adjustment value of focus backrush pulse
(0<=ABR<=12)
AF_WIDE: ZW
ZW: adjustment value of focus at zoom position wide
(–44<=ZW<=47)
Camera
Collimator
COMPL PWB CP-1
Lens
Adjustment
AWB
Adjustment
CCD White Point
Defect Detect
Adjustment
CCD Black Point
And White Point
Defect Detect
Adjustment In
Lighted
Factory
Cord
Setting
USB storage
information
registration
Language
Setting
COMPL PWB TB-1
LENS ASSY
3-6. The adjustment item which in necessary in part exchange
Reset
Setting
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
DscCalDi
x
OK
Focus Result
PZ_SW: 954
PZ_BR: 22
PZ_SP: 264
AF_SW: 932
AF_BR: 7
AF_WIDE: 9
AF_MID1: -6
AF_MID2: -15
AF_MID3: -7
AF_TELE: -2
!