– 16 –
3. ELECTRICAL ADJUSTMENT
3-1. Table for Servicing Tools
Download the calibration software and the firmware
from the following URL.
http://www.digital-sanyo.com/overseas/service/
3-2. Equipment
1. AC adaptor
2. PC (IBM R -compatible PC, Pentium processor, Window
98 or Me or 2000 or XP)
3. DC adaptor
3-3. Adjustment Items and Order
1. Lens Adjustment
2. AWB Adjustment
3. CCD White Point Defect Detect Adjustment
4. CCD Black Point And White Point Defect Detect Adjust-
ment In Lighted
Note: Item 1-4 adjustments should be carried out in sequence.
3-4. Setup
1. System requirements
Windows 98 or Me or 2000 or XP
IBM R -compatible PC with pentium processor
USB port
40 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Installing USB driver
Install the USB driver with camera or connection kit for PC.
3. Pattern box (color viewer)
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100
±
20 K and luminosity to 900
±
20 cd/m
2
. Be careful of handling
the lump and its circumference are high temperature during
use and after power off for a while.
4. Computer screen during adjustment
Ref. No.
Name
Part code
J-1
J-2
J-3
VJ8-0190
Pattern box (color viewer)
Calibration software
J-4
Number
1
1
1
Chroma meter
VJ8-0192
1
Spare lump
VJ8-0191
J-5
J-1
J-3
J-4
J-5
1
Discharge jig
VJ8-0188
J-6
1
Collimator
VJ8-0260
Firmware
Data
AWB
Focus
UV Matrix
R Bright
RGB Offset
Tint
B Bright
Gain
Phase
LCD
Calibration
Upload
PAF Cal.
LCD Type
H AFC
Test
VCOMDC
VCOMPP
Cal Data
Cal Mode
OK
OK
EVF
USB storage
Get
Set
VID
Set
PID
Set
Serial
Set
Rev.
Set
Setting
Language
Video Mode
VCO
Factory Code
Hall Cal.
Backrush pulse :
Set
Get
J-7
1
Spare lump (collimator)
VJ8-0282