![Sanyo VSP-8000 Instruction Manual Download Page 21](http://html.mh-extra.com/html/sanyo/vsp-8000/vsp-8000_instruction-manual_360359021.webp)
MULTIPLEXER OPERATION
The VSP-8000 enables two methods of multiplexer operation. One is performing direct operation using the command buttons on the
VSP-8000 [A] and the other is by using the call-up commands to bring up commands to the menu screen [B]. Some multiplexers are
equipped with a matrix switching function (for spot monitor screen setting), and some are not. The system controller automatically
detects which type of multiplexer is connected.
[A] Operation using the command buttons
Use the procedure outlined below to operate the multiplexers.
Operating procedure
1. Press the INDIVIDUAL button.
2. Press the MODE button to change the displayed device to
“MX”.
3. Enter the address with the numeric keypad.
4. Press the ENTER button to check the address status.
•
The operating status of the multiplexer appears in the
menu screen. (Refer to Checking the address.)
5. Press the desired command buttons located in the
MULTIPLEXER section of your VSP-8000.
•
For an explanation of the multiplexer command buttons,
refer to the Command button operation list on page 21.
Checking the address
When the address is checked in step 4,
the operating status of the multiplexer
appears in the menu screen.
Status
Operating condition
L: MULTI
Live picture mode, multi-screen (9-screen/16-screen
full screen)
V: MULTI
Video playback mode, multi-screen
(9-screen/16-screen full screen)
L: QUAD
Live picture mode, quad-screen
L: QUAD: S
Live picture mode, quad-screen, sequential display
L: PLUS 16
Live picture mode, plus screen, 16-screen full screen
L: PLUS: S
Live picture mode, plus screen, sequential display
L: FULL: S
Live picture mode, full screen sequential display
L: FULL: 16
Live picture mode, 16-channel full screen
M2SET: 16*
1
16-channel full screen for monitor 2
M2SET: S*
1
Sequential display for monitor 2
SPOT2:01*
2
1-channel full screen for spot monitor 2
SPOT2:S*
2
Sequential display for spot monitor 2
MENU
Menu screen
SERIES
The multiplexer is digital and if it is connected in series,
the main monitor display is activated by the LIVE
button on the device to be displayed.
If a “V” appears instead of an “L”, the mode is video or digital video
recorder playback mode.
*1: When matrix switching function is not available
*2: When matrix switching function is available
V R : - -
-
S A N Y O C o n t r o l l e r
1 5 : 3 0 : 3 0
M X : - -
-
M X : - -
1
2 N D F L O O R
M X : 0 0 1 L : M U L T I
M X : 0 0 1 < S E Q >
M X : 0 0 1
INDIVIDUAL
1 Device display
3 Address entry
4 Address check
5 Operation
execution
(Example)
1
2
3
4
5
6
7
8
9
0
M X : 0 0 1 < Q U A D >
M X : 0 0 1 < M U L T I >
M X : 0 0 1 < L I V E >
SEQ
QUAD
MULTI
LIVE
☞
Refer to “Checking the Address”
Device title (
☞
P13)
CLEAR
CLEAR
CLEAR
CLEAR
ENTER
MULTI
QUAD
PLUS
MULTIPLEXER
STILL
SEQ
CAM
MPX
MON2
SPOT
VCR
LIVE
EXIT
BACK
NEXT
FULL
Multiplexer
Timelapse VCR
Camera
Digital video
recorder
M X : - -
-
V R : - -
-
C M : - -
-
D R : - -
-
M X : - -
-
2 Device selection
MODE
Operating status
M X : 0 0 1 L : M U L T I
L8CSB/XE (VSP-8000 GB) 2002. 4. 4
20