– 18 –
3-7. Adjust Specifications
[CP1 board (Side B)]
Note:
1.
–
6 V (A) voltage adjustment is necessary to repair in the
CP1 board and replace the parts.
1. –6V (A) Voltage Adjustment
Adjustment method:
1. Isolate the CP1 circuit board.
2. Use a lead wire to short-circuit CL301 and CL302.
3. Use the accessory AC adapter or a DC power supply to
apply 5 V to the DC jack (JK501).
4. Turn VR502 to adjust the voltage to -6.0
±
0.1 V.
5. Disconnect the lead wire between CL301 and CL302 which
was connected in step 2.
3-6. The adjustment item which in necessary in part exchange
COMPL PWB CP-1
Lens
Adjust-
ment
AWB
Adjust-
ment
CCD White
Point Defect
Detect
Adjustment
CCD Black Point
And White Point
Defect Detect
Adjustment In
Lighted
Factory
Cord
Setting
USB storage
information
registration
Language
Setting
COMPL PWB ST-1
COMPL PWB VF-1
Reset
Setting
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
LENS ASSY
ASSY FLEXIBLE
PWB CA1
COMPL PWB TB-1
Gyro sensor
zero offset
adjustment
-6 V (A)
Voltage
Adjust-
ment
COMPL PWB TB-2
Measuring Point
ADJ. Location
Measuring Equipment
CL502
Digital voltmeter
VR502
ADJ. Value
–
6.0
±
0.1 V
VR502
CL502
CL302
CL301