– 18 –
3-7. Adjust Specifications
1. Lens Adjustment (Infinity)
Preparation:
POWER switch: ON
If using a ready-made collimator, set to infinity.
Note:
Do not vibrate during the adjustment.
If readjusting after it has already been adjusted, wait for 15
minutes or more for the unit to cool down first.
Adjustment method:
1. Set the camera 0 cm from the collimator. (Do not enter any
light.)
2. Set the camera so that it becomes center of the screen in
the collimator.
3. Double-click on the DscCalDi.exe.
4. Click the “QrCode”.
5. QrCode Input Dialog display will be displayed.
6. Deselect Bar code Input.
7. Enter the alphanumeric characters which are underneath
the bar code which is included with the lens.
8. Click the Execute.
9. Status: Production adjustment end! will be displayed, and
click the OK.
10. Select “Infinity Cal.” on the LCD “Test”, and click the “Yes”.
11. Lens infinity adjustment value will appear on the screen.
12. Click the OK.
2. Lens Adjustment (1m) is carried out after this adjust-
ment.
3-6. The adjustment item which in necessary in part exchange
Camera
Collimator
COMPL PWB CP-1
Factory
Cord
Setting
Language
Setting
COMPL PWB VF-1
COMPL PWB ST-1
COMPL PWB ST-2
Reset
Setting
COMPL PWB TB-3
Lens
Adjust-
ment
(1 m)
AWB
Adjust-
ment
USB
storage
information
registration
CCD White
Point
Defect
Detect
Adjustment
CCD Black
Point And
White Point
Defect Detect
Adjustment
In Lighted
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
COMPL PWB TB-1
COMPL PWB TB-2
Lens
Adjust-
ment
(Infinity)
ASSY FPC, CA1