– 21 –
Adjustment value determination is effectuated using the "AGC",
“CHECK", “CHECK_ND”, “IRIS_GAIN”, “IRIS_OFFSET”, "MS",
“MS_M”, “MS_C”, “MS_C2”, “MS_C3”, “IRIS_PWM1”,
“IRIS_PWM2”, “IRIS_PWM3” and “IRIS_PWM4” values. If
AGC= a1
CHECK= wc0, wc1, wc2
CHECK_ND= wnc0, wnc1, wnc2
IRIS_GAIN= g,
IRIS_OFFSET= o,
MS= ms1, ms2,
MS_M= ms3, ms4,
MS_C= ms5, ms6,
MS_C2= ms7, ms8,
MS_C3= ms9
IRIS_PWM1= s1, s2
IRIS_PWM2= s3, s4
IRIS_PWM3= s5, s6
IRIS_PWM4= s7
the adjustment values fulfill the conditions below, they are de-
termined as within specifications.
Adjustment value determination
a1<=2610
wc0=128
±
2, wc1=128
±
2, wc2<=255
wnc0=128
±
2, wnc1=128
±
2, wnc2<=255
0<=g<=255
0<=o<=255
3100<ms1<4500, 600<ms2<2000, 2771<ms3<4171,
2044<ms4<3444, 1592<ms5<2992, 1109<ms6<2509,
1000<ms7<2400, 829<ms8<2229, 676<ms9<2076
0<=s1<=255, 0<=s2<=255, 0<=s3<=255, 0<=s4<=255,
0<=s5<=255, 0<=s6<=255, 0<=s7<=255
s1>s2>s3>s4>s5>s6>s7
Adjustment values other than the above are irrelevant.
Camera
Pattern box
4. CCD White Point Defect Detect Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Double-click on the DscCalDi.exe.
2. Select “CCD Defect” on the LCD “Test”, and click the “Yes”.
3. After the adjustment is completed, OK will display.
4. Click the OK.
5. CCD Black Point And White Point Defect Detect
Adjustment In Lighted
Preparation:
POWER switch: ON
Setting of pattern box:
Color temperature: 3100
±
20 (K)
Luminance: 900
±
20 (cd/m
2
)
Adjusting method:
1. Set the camera 0 cm from the pattern box. (Do not enter
any light.)
2. Double-click on the DscCalDi.exe.
3. Select “CCD Black” on the LCD “Test”, and click the “Yes”.
4. After the adjustment is completed, the number of defect
will appear.
5. Click the OK.