8
-
3. ELECTRICAL ADJUSTMENT
3-1. Table for Servicing Tools
Download the calibration software and the firmware
from the following URL.
http://www.digital-sanyo.com/overseas/service/
Place the DscCalDi.exe file, camapi32.dll file and
QrCodeInfo.dll file together into a folder of your
choice.
The version of calibration software should use 1.61b
or subsequent ones.
3-2. Equipment
1. PC (IBM® -compatible PC, Pentium processor, Window
2000 or XP)
2. Frequency counter
3.Monitor TV
3-3. Adjustment Items and Order
1. Timer Quartz Adjustment
2. Lens Adjustment (Infinity)
3. Lens Adjustment (1m)
4. Privacy Masking Adjustment
5. AWB Adjustment
6. CCD White Point Defect Detect Adjustment
7. CCD Black Point And White Point Defect Detect Adjust-
ment In Lighted
Note: If the lens, CCD and board and changing the part, it is
necessary to adjust again. Item 1-7 adjustments should be
carried out in sequence.
3-4. Setup
1. System requirements
Windows 2000 or XP
IBM®-compatible PC with pentium processor
USB port
40 MB RAM
Hard disk drive with at least 15 MB available
VGA or SVGA monitor with at least 256-color display
2. Pattern box
Turn on the switch and wait for 30 minutes for aging to take
place before using Color Pure. It is used after adjusting the
chroma meter (VJ8-0192) adjust color temperature to 3100 ±
20 K and luminosity to 900 ± 20 cd/m
2
. Be careful of handling
the lump and its circumference are high temperature during
use and after power off for a while.
3. Computer screen during adjustment
3-5 Connecting the camera to the computer
Chang the camera for the device mode according to the
procedure as follows when connecting it with “COM-
PUTER” and adjusting, and inspecting it.
1. It becomes a device mode if it turns on power while
pushing a top and bottom of the operation paner key at
the same time.
2. Confirm that LED of the front panel blinks.
3. Device mode of the camera is carried out and it connects
with a personal computer by the USB cable.
Device mode is reset when turning off power.
Ref. No.
Name
Part code
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
Number
1
1
1
1
1
1
1
1
J-1
J-3
J-4
VJ8-0190
VJ8-0192
VJ8-0191
VJ8-0260
VJ8-0282
Pattern box
Calibrationsoftware
Chroma meter
Spare lump
Collimator
Spare lump (collimator)
Siemens star chart
USB “A” to “A” cable
Firmware
QrCode
AWB
Focus
UV Matrix
R Bright
RGB Offset
Tint
B Bright
Gain
Phase
LCD
Calibration
Upload
Initialize
LCD Type
H AFC
Test
VCOMDC
VCOMPP
Cal Data
Cal Mode
OK
OK
EVF
USB storage
Get
Set
VID
Set
PID
Set
Serial
Set
Rev.
Set
Setting
Language
Video Mode
VCO
Factory Code
Backrush pulse :
Set
Get
J-8