11
-
4. Privacy Masking Adjustment
Preparation:
POWER switch: ON
Adjustment method:
1. Set the camera unit lens 10 ± 5 mm from the collimator.
(Do not enter any light.)
2. Set the camera so that it becomes center of the screen in
the collimator.(Tele side)
3. Device mode of the camera is carried out and it connects
with a personal computer by the USB cable.
4. Double-click on the DscCalDi.exe.
5. Select “Privacy Mode” on the LCD “Test”.
6. Select “Privacy Mode” on the LCD “Privacy mask”.
7. “Wide” is click and it is made a wide side.
8. From the center of a privacy masking chart, masking
area is adjusted by "Left" and "Right" so that left and
right may become equal, and the upper and lower sides
may become equal by "Up" and "Down".
9. “Tele” is click and it is made a tele side.
10. Ceck that there is an even amount of space between
the masking area on the TELE screen and the top,
bottom, left and right edges of the monitor screen.
If there is a large amount of difference in the spaces, re-
adjust.
Camera
Collimator
10 5 mm
Down
Up
Right
Left
Privacy Mode
Privacy mask
Tele
Wide
OK