(OTHERS) MENU SETTINGS
AND SETUP
MENU 3
The (OTHERS) menu lets you setup the autorepeat
mode, the TAPE END OUT output terminal signal
timing, the alarm mode, the clog detection mode and
the data transfer speed when using the RS-232C
connector.
1
Press the MENU button to display the MENU 3
(OTHERS).
Autorepeat Recording Mode Setup
2
Press the SHIFT
]
button, until the “REPEAT”
setting is flashing.
3
Press the REC/PLAY SPEED
l
(or
j
) button to
set the desired autorepeat recording mode.
MODE 1 . . . . . . . . The autorepeat mode is
automatically canceled if
there is an alarm trigger.
MODE 2 . . . . . . . . Autorepeat recording takes
place even if there is an
alarm trigger.
•
Press the SEARCH/AUDIO ON button to
complete the setting procedure and return to the
normal screen display.
TAPE END OUT Terminal Output Setup
4
Press the SHIFT button.
°
The “TAPE END” setting starts flashing.
5
Press the REC/PLAY SPEED
l
(or
j
) button to
set the desired recording TAPE END OUT terminal
output mode.
–3M. . . . . . . . . . . . The output at the TAPE
END OUT terminal will
become 0 V (Low) when the
tape counter reaches
“2
H
57
M
00
S
” and/or when
the tape reaches the end.
END . . . . . . . . . . . The output at the TAPE
END OUT terminal will
become 0 V (Low) when the
tape reaches the end.
•
Press the SEARCH/AUDIO ON button to
complete the setting procedure and return to the
normal screen display.
Alarm Mode Setup
6
Press the SHIFT
]
button.
°
The “ALARM MODE” setting starts flashing.
7
Press the REC/PLAY SPEED
l
(or
j
) button to
set the desired alarm mode.
Y. . . . . . . . . . . . . . Alarm recording is done
when there is an alarm
trigger.
Y1. . . . . . . . . . . . . Alarm recording is done only
when there is an alarm
trigger during programmed
timer recording.
Y2. . . . . . . . . . . . . Alarm recording is done only
if there is an alarm trigger
and the VCR is not in
programmed timer recording
mode.
N. . . . . . . . . . . . . . Alarm recording is not
performed even if there is
an alarm trigger.
•
Press the SEARCH/AUDIO ON button to
complete the setting procedure and return to the
normal screen display.
Clog Detection Setup
8
Press the SHIFT
]
button.
°
The “CLOG DETECT.” setting starts flashing.
9
Press the REC/PLAY SPEED
l
(or
j
) button to
set the desired mode.
Y. . . . . . . . . . . . . . The recording quality is
monitored automatically.
When the heads are dirty
and the recording quality
deteriorates, the output at
the WARNING OUT
terminal becomes 0V (Low),
the “
m
” indicator flashes on
the digital display, and the
buzzer sounds.
N. . . . . . . . . . . . . . The recording quality is not
monitored.
•
Press the SEARCH/AUDIO ON button to
complete the setting procedure and return to the
normal screen display.
Continued on the next page.
«
MENU 3 (Initial screen)
<BUZZER SET>
ALARM IN Y
TAPE END Y
KEY IN N
<OTHERS>
REPEAT MODE1
TAPE END -3M
ALARM MODE Y
CLOG DETECT. Y
RS-232C 1200
GB
FE4QS/EX (TLS-S7000P GB) Wed. Mar., 24/1999
English
29