4
2-2. Major Component Specifications
2-2-1. Indoor Unit
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Part No.
POW – K181GJHA
Controls
Microprocessor
Control circuit fuse
250 V – 3.15 A
Remote Control Unit
RCS – 2HS4E
Type
Cross-flow
Q´ty ... Dia. and length
mm
1 ... ø88 / L746
Fan motor model ... Q´ty
UF2– 31A5P– S ... 1
No. of poles .... Hi rpm (Cool / Heat)
2 ... 1,335 / 1,215
Nominal output
W
30
Coil resistance (Ambient temp. 20°C)
Ω
WHT – BRN : 133.7
WHT – PNK : 168.4
– :
–
– :
–
– :
–
Safety
Type
Thermal protector
devices
Operating temp.
Open
°C
130 ± 8
Close
Automatic reclosing
Run capacitor
µF
2.0
VAC
440
Type
Stepping motor
Model
MP24GA2
Rating
DC 12 V
Coil resistance (Ambient temp. 20°C)
k
Ω
Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.3
Face area
m2
0.156
Heat
Exch. Coil
Flap Motor
Fan & Fan Motor
Controller
PCB
Indoor Unit
SAP – K181AHA