WARNING:
The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side of
the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is
identified with the line (
) in the schematic diagram. For continued product safety and protection of person-
nel injury, servicing should be made with qualified personnel.
The following precautions must be observed.
SAFETY PRECAUTIONS
1: An isolation transformer should be connected in the
power line between the projector and the AC line
before any service is performed on the projector.
2: Comply with all caution and safety-related notes
provided on the cabinet back, cabinet bottom, inside
the cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always
be certain that all the protective devices are
installed properly, such as, control knobs, adjust-
ment covers or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND
PROPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no
stray parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe
to operate without danger of electric shock.
SERVICE PERSONNEL WARNING
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always
turn off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages(15kV - 20kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
PRODUCT SAFETY NOTICE
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there
parts must be made by exactly the same parts.
■
Safety Instructions
- 3 -
Summary of Contents for PLV-Z4
Page 91: ... 91 SiI9011 HDMI Receiver IC8001 IC Block Diagrams ...
Page 112: ...M4W Z400 112 Mechanical and Optical Parts List 9 43 44 S5 S14 S12 S5 55 54 25 76 ...
Page 113: ...M4W Z400 113 Mechanical and Optical Parts List 1 12 5 46 45 61 51 47 49 ...
Page 115: ...M4W Z400 115 Mechanical and Optical Parts List 64 52 63 57 66 66 65 65 56 ...
Page 117: ...M4W Z400 117 Mechanical and Optical Parts List S7 S7 S10 S10 103 70 69 68 S7 S10 109 71 67 ...
Page 122: ...M4W Z400 MEMO 122 ...
Page 123: ...M4W Z400 123 MEMO ...
Page 124: ... M4WA Oct 2005 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 138: ...Diagrams Drawings M4WA ...