background image

 

 

 

 

EXPAND SERIAL COMMAND 

FUNCTIONAL SPECIFICATIONS 

 

PLV-HD2000 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SANYO Electric Co., Ltd 

Home Electronics Group 

AV Company 

Projector Business Unit 

 

 

Summary of Contents for PLV-HD2000

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLV HD2000 SANYO Electric Co Ltd Home Electronics Group AV Company Projector Business Unit ...

Page 2: ...Table 8 6 2 Display Status Read Command Table 8 6 3 Video Status Read Command Table 8 6 4 Input Status Read Command Table 9 6 5 Screen Status Read Command Table 9 6 6 Lamp Status Read Command Table 9 6 7 Setting Status Read Command Table 10 6 8 Other Status Read Command Table 10 7 Error Code Table 10 8 Functional Execution Command 11 8 1 Format 11 8 2 Transfer Example 11 8 3 Operation Requirements...

Page 3: ...ut Status Read Command 39 9 7 Screen Status Read Command 45 9 8 Lamp Status Read Command 46 9 9 Setting Status Read Command 48 9 10 Other Status Read Command 51 10 Command with Address Specification 54 10 1 Overview 54 10 2 Functional Execution Command with address 55 10 3 Status Read Command with Address 56 ...

Page 4: ... 2 Serial Interface Specification 2 1 Communication Specification Items Specification Synchronoun System Asynchronous Transmission Speed 9600 19200 Data Length 8 bits Parity N A Stop Bit 1 Flow Control N A Note1 Transmission speed initial setting value is 19200 Note2 Transmission speed can be changed in Service Mode 2 2 Connection Dedicated serial cables that come with the projector must be used f...

Page 5: ...CF_BRIGHT_032 CR Next Command Projector PC 000 CR Response A few ms 5s When the command is sent without waiting for the response to the previous command the projector may not operate properly Howerver this is not the case when there is no response for more than 5 seconds Projector takes about 5 seconds for internal initialization after plugging in AC power During this time projector cannot process...

Page 6: ... 3 CR Set value of Gamma Balance 5 2 Display Command Table Execute command Item CF_FSYNC_ 1 CR Set value of Fine Sync CF_TODOTS_ 1 CR Set value of Total Dots CF_CLAMP_ 1 CR Set value of Clamp CF_H POS_ 1 CR Set value of Horizontal Position CF_V POS_ 1 CR Set value of Vertical Position CF_DLINE_ 1 CR Set value of Display Line CF_DDOTS_ 1 CR Set value of Display Dots CF_SETDISPADJ_ 1 CR Apply values...

Page 7: ...CR Switch ON OFF of auto lamp control 5 6 Setting Command Table Execute command Item CF_BBACK_1 CR Set Cancel Blue Back function CF_DISP_ 1 CR Set Cancel Display function CF_LOGO_ 1 CR Set Cancel Logo function CF_CEIL_ 1 CR Set Cancel Ceiling function CF_REAR_ 1 CR Set Cancel Rear function CF_RCODE_ 1 CR Select Remote Control Code CF_LANG_ 1 CR Select language for OSD CF_ON STA_ 1 CR Set Power ON ...

Page 8: ...et selected Image mode CR_IMGGMD CR Get selected Image Gamma mode CR_APCTRL CR Get setting status of Auto Picture Control CR_BBAL CR Get setting status of Gamma Balance 6 2 Display Status Read Command Table Status read command Item CR_FSYNC CR Get value of Fine Sync CR_TDOTS CR Get value of Total Dots CR_CLAMP CR Get value of Clamp CR_H POS CR Get value of Horizontal Position CR_V POS CR Get value...

Page 9: ...Input 3 CR_NMSLOT4 CR Get Slot board name inserted to Input 4 CR_IDSLOT1 CR Get Slot board ID inserted to Input 1 CR_IDSLOT2 CR Get Slot board ID inserted to Input 2 CR_IDSLOT3 CR Get Slot board ID inserted to Input 3 CR_IDSLOT4 CR Get Slot board ID inserted to Input 4 6 5 Screen Status Read Command Table Status read command Item CR_SCREEN CR Get selected screen size CR_VSCALE CR Get value of V Sc...

Page 10: ...ead command Item CR_PRESSURE CR Get Air Pressure data CR_SIGNAL CR Get Signal status if there is signal or not CR_VMUTE CR Get setting status of No Show CR_FREEZE CR Get setting status of Freeze CR_INFPFAIL CR Get the information on Power Failure CR_TEMPWARN CR Get temperature status whether it is close to abnormmal level or not CR_TEMPFAIL CR Get temperature in abnormal temperature status 7 Error...

Page 11: ...tor returns CR 8 2 Transfer Example When setting total dots for the projector to 1344 by Expand Serial Command PC PJ CF_TODOTS_1344 CR PC PJ 000 CR Acceptable 8 3 Operation Requirements Functional Execution Command is limited when the projector is in the following status However Status Read Command is effective under these conditions Projector Status Valid Function Execution Command In Standby mod...

Page 12: ... the power is turned to ALL OFF status the value returns to the original setting It is stored in Standby mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly specify setting value of Color UP Increment setting value of Color by 1 DN Decrement setting value of Color by 1 Details Set Color value valid only when it is in the norma...

Page 13: ... DN Decrement setting value of Gamma by 1 Details Set Gamma value valid only when it is in the normal Power ON status The value set by this command is not stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Standby mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_W...

Page 14: ...ion level to L2 L3 Set Noise Reduction level to L3 Details Set Cancel Noise Reduction valid only when it is in the normal Power ON status The value set by this command is not stored in the projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Standby mode Acceptable 000 CR Response Unacceptable Error Code CR 8 4 10 CF_PROG...

Page 15: ... Image1 to Image10 displayed in the projector OSD menu on selecting Image The value set by this command is stored in EEPROM so that the setting can remain effective evern after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 4 12 CF_IMAGEADJ Command Command CF_IMAGEADJ_ 1 CR 1 RST Reset adjusted value for the Image STR1 Store current adjusted value to ...

Page 16: ...cceptable 000 CR Response Unacceptable Error Code CR 8 4 14 CF_BBAL Command Command CF_BBAL 1_ 2_ 3 CR 1 R Red G Green B Blue 2 0 2 Point 0 140 Point 1 300 Point 2 600 3 32 032 Offset value of Gamma adjustment at the point specified in 2 000 is the center value Details Set Offset value ot Gamma adjustment at the specifiyed point valid only when it is in the normal Power ON status Therefore when th...

Page 17: ...s value Only valid when it is in the normal Power ON status The value set by this command is not stored in projector s memory Therefore when the power is turned to ALL OFF status the value returns to the original setting It is stored in Standby mode Note When 1 is directly specified CF_SETDISPADJ as well as this command is requied In order to apply the setting value to the display image Acceptable...

Page 18: ...ll as this command is requied In order to apply the setting value to the display image Acceptable 000 CR Response Unacceptable Error Code CR 8 5 5 CF_V POS Command Command CF_V POS_ 1 CR Input is PC 0000 nnnn Directly specify settting value of Vertical Position nnnn indicates maximum value which is current value of Total Line Display Line UP Increment setting value of Vertical Position by 1 DN Dec...

Page 19: ...play image Acceptable 000 CR Response Unacceptable Error Code CR 8 5 7 CF_DDOTS Command Command CF_DDOTS_ 1 CR Input is PC 0100 nnnn Directly specify setting value of Display Dots nnnn indicates maximum value This value equals to the current value of Total Dots Horizontal Position 1 UP Increment setting value of Display Dots by 1 DN Decrement settinfg value of Display Dots by 1 1 Input is Video 01...

Page 20: ...screen image without this command valid only when it is in the normal Power ON status CF_FSYNC CF_TDOTS CF_CLAMP CF_H POS CF_V POS CF_DLINE CF_DDOTS Note When 1 is EXT21 EXT60 send CF_SYSTEM command ExMode should be displayed in System box Acceptable 000 CR Response Unacceptable Error Code CR 8 5 9 CF_ORGMODE Command Command CF_ORGMODE_ 1 CR 1 XGA1 HDTV1080i60 Etc Details Select the original signa...

Page 21: ...s to Mode18 19 Store current Display adjust status to Mode19 20 Store current Display adjust status to Mode20 Details Store the current Display adjustment status each parameter such as Total dots to Custom Mode1 Mode20 This command works the same way as storing to Mode1 Mode20 in Display adjust menu Only valid when it is in the normal Power ON status Acceptable 000 CR Response Unacceptable Error C...

Page 22: ...CE_ 1 CR 1 DIGITAL Select DVI Digital of computer ANALOG Select Analog input of computer VIDEO Select Composite Video input S VIDEO Select S Video input SCART Select SCART Input HDCP Select HDCP Input YC Select Y C input YPBPR Select Y Pb Pr input YPBCR Select Y Cb Cr input SDI1 Select SDI1 input SDI2 Select SDI2 input DUAL1 Select Dual YCbCr1 input DUAL2 Select Dual YcbCr2 input DUAL3 Select Dual...

Page 23: ...o Input SCART Select SCART Input HDCP Select HDCP Input YC Select Y C Input YPBPR Select Y Pb Pr Input YPBCR Select Y Cb Cr Input SDI1 Select SDI1 Input SDI2 Select SDI2 Input DUAL1 Select Dual YCbCr1 input DUAL2 Select Dual YcbCr2 input DUAL3 Select Dual YcbCr3 input DUAL4 Select Dual YcbCr4 input DUAL5 Select Dual RGB1 input DUAL6 Select Dual RGB2 input Details Select Input specified in 1 and al...

Page 24: ...SC NTSC443 Select NTSC4 43 PAL Select PAL SECAM Select SECAM PAL M Select PAL M PAL N Select PAL N 1080I60 Select 1080i 60Hz 1080I50 Select 1080i 50Hz 1035I Select 1035i 720P Select 720p 575P Select 575p 480P Select 480p 575I Select 575i 480I Select 480i 1080P30 Select 1080p30 1080PSF30 Select 1080psf30 MODE1 MODE15 Select Mode1 15 EXST21 EXT60 Select ExMode21 60 Details Select system for currentl...

Page 25: ...7 2 CF_VSCALE Command Command CF_VSCALE_ 1 CR 1 032 32 031 31 002 2 001 1 000 0 01 1 02 2 31 31 32 32 UP Increment V Scale setting value by 1 DN Decrement V Scale setting value by 1 Details Set V Scale value valid only when it is in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 7 3 CF_VPOS Command Command CF_VPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 ...

Page 26: ...etails Set H Scale value valid only when it is in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 7 5 CF_HPOS Command Command CF_HPOS_ 1 CR 1 015 15 014 14 002 2 001 1 000 0 01 1 02 2 14 14 15 15 UP Increment H Position setting value by 1 DN Decrement H Position setting value by 1 Details Set H Position value valid only when it is in the normal Power ON status Ac...

Page 27: ...red in EEPROM of the projector so its setting is effective even after the power is turned to ALL OFF status Full mode means 4 lamps are lit while 3L mode means half of the total number of lamps are lit but which ones are lit is automatically determined The lamps with less total running time are chosen Acceptable 000 CR Response Unacceptable Error Code CR 8 8 3 CF_AUTOLAMPCONTRL Command Command CF_...

Page 28: ...of the projector so its setting is effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 9 3 CF_LOGO Command Command CF_LOGO_ 1 CR 1 ON Set Logo to ON OFF Set Logo to OFF Details Set Cancel Logo valid only when it is in the normal Power ON status The status set by this command is stored in EEPROM of the projector so its setting is effect...

Page 29: ...R Response Unacceptable Error Code CR 8 9 7 CF_LANG Command Command CF_LANG_ 1 CR 1 ENG Select English DEU Select German FRA Select French ITA Select Italian ESP Select Spanish POR Select Portuguese NED Select Dutch SVE Select Swedish CHI Select Chinese KOR Select Korean JPN Select Japanese RUS Select Russian Details Set language for OSD valid only when it is in the normal Power ON status The lang...

Page 30: ...d only when it is in the normal Power ON status The status set by this command is stored in EEPROM of the projector so its setting is effective even after the power is turned to ALL OFF status Acceptable 000 CR Response Unacceptable Error Code CR 8 9 11 CF_FANSPEED Command Command CF_FANSPEED_ 1 CR 1 MAX Set to Maximum Fan Speed NOR Set to Normal Fan Speed Details Switch speed of Fan Control valid...

Page 31: ...nctional Specifications 31 56 8 9 13 CF_FDEFAULT Command Command CF_FDEFAULT_ 1 CR 1 RST Details Set Factory Default setting values valid only when it is in the normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR ...

Page 32: ...ommand String 2 When a projector receives the applicable command it returns required data as a string 000_ 1 CR 1 Required data String Refer to Basic Status Read Command Table 3 When the received data cannot be decoded the projector returns CR 9 2 Transfer Example Get total dots of the projector by Expand Serial Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR ...

Page 33: ... Error Code CR 9 3 3 CR_COLOR Command Command CR_COLOR CR Details Get value of Color Acceptable 000_ 1 CR 1 000 063 Response Unacceptable Error Code CR 9 3 4 CR_TINT Command Command CR_TINT CR Details Get value of Tint Acceptable 000_ 1 CR 1 000 063 Response Unacceptable Error Code CR 9 3 5 CR_SHARP Command Command CR_SHARP CR Details Get value of Sharpness Acceptable 000_ 1 CR 1 000 031 Response ...

Page 34: ...n value of White Balance Acceptable 000_ 1 CR 1 000 063 Response Unacceptable Error Code CR 9 3 9 CR_WBAL B Command 9 3 10 CR_COLTEMP Command Command CR_COLTEMP CR Details Get setting status of Color Temp Acceptable 000_ 1 CR 1 000 Xlow 001 Low 002 Mid 003 High BLANK OSD Menu is blank Neither of Xlow Low Mid High Response Unacceptable Error Code CR Command CR_WBAL B CR Details Get Blue value of Wh...

Page 35: ...to ON OFF Progressive is set to OFF Response Unacceptable Error Code CR 9 3 13 CR_IMAGE Command Command CR_IMAGE CR Details Get setting status of Image Acceptable 000_ 1 CR 1 STANDPC Standard PC STANDAV Standard AV REAL Real CINEMA Cinema CUSTOM1 Image 1 CUSTOM2 Image 2 CUSTOM3 Image 3 CUSTOM4 Image 4 CUSTOM5 Image 5 CUSTOM6 Image 6 CUSTOM7 Image 7 CUSTOM8 Image 8 CUSTOM9 Image 9 CUSTOM10 Image 10...

Page 36: ...he value of point 0 2 The range of each value is 32 to 032 Response Unacceptable Error Code CR 9 4 Display Status Read Command 9 4 1 CR_FSYNC Command Command CR_FSYNC CR Details Get value of Fine Sync Acceptable 000_ 1 CR Input is Computer 0000 0031 1 Input is Video 0000 0031 Response Unacceptable Error Code CR 9 4 2 CR_TDOTS Command Command CR_TDOTS CR Details Get Total Dots value Acceptable 000_...

Page 37: ...n nnnn Total Line Display Line 1 Input is Video mmm nnnn Response Unacceptable Error Code CR 9 4 6 CR_DLINE Command Command CR_DLINE CR Details Get Display Line value Acceptable 000_ 1 CR Input is Computer 0100 nnnn nnnn Total Line Vertical Position 1 Input is Video 0100 nnnn nnnn initial value when signal is changed Response Unacceptable Error Code CR 9 4 7 CR_DDOTS Command Command CR_DDOTS CR De...

Page 38: ...FFF Mode 1 is Stored the others are Free FFFFFFFFFFFFFFFFFFFS Mode 20 is Stored the others are Free SSSSSSSSSSSSSSSSSSSS ALL modes are Stored Response Unacceptable Error Code CR 9 4 10 CR_SETDISPADJ Command Command CR_SETDISPADJ CR Details Get signal type of currently displayed in system Acceptable 000_ 1 CR 1 PAL SECAM XGA1 1080I60 MODE16 EXT24 Etc Response Unacceptable Error Code CR 9 5 Status R...

Page 39: ...ALOG Analog Input is selected VIDEO Video Input is selected S VIDEO S Video Input is selected SCART SCART input is selected HDCP HDCP input is selected YC Y C input is selected YPBPR Y Pb Pr input is selected YPBCR Y Cb Cr input is selected SDI1 SDI1 input is selected SDI2 SDI2 input is selected DUAL1 Dual YcbCr1 input is selected DUAL2 Dual YcbCr2 input is selected DUAL3 Dual YcbCr3 input is sele...

Page 40: ...YcbCr2 input is selected DUAL3 Dual YcbCr3 input is selected DUAL4 Dual YcbCr4 input is selected DUAL5 Dual RGB1 input is selected DUAL6 Dual RGB2 input is selected BLANK There is no source NOCARD There is no board inserted Response Unacceptable Error Code CR 9 6 4 CR_SRCINP2 Command Command CR_SRCINP2 CR Details Get Source of Input 2 Acceptable 000_ 1 CR 1 The same data as CF_SRCINP1 Response Una...

Page 41: ...d 1 Input is Video AUTO Auto is selected NTSC NTSC is selected NTSC443 NTSC4 43 is selected PAL PAL is selected SECAM SECAM is selected PAL M PAL M is selected PAL N PAL N is selected 1080I60 1080i60Hz is selected 1080I50 1080i50Hz is selected 1035I 1035i is selected 720P 720p is selected 575P 575p is selected 480P 480p is selected 575I 575i is selected 480I 480i is selected 1080P30 1080p30 is sel...

Page 42: ...ST CR Details Get possible modes in the list Acceptable 000_ 1_ 2_ _ x CR 1 MODE1 MODE2 MODE3 MODE18 MODE19 MODE20 Response Unacceptable Error Code CR 9 6 10 CR_HMSLOT Command Command CR_HMSLOT CR Details Get the total number of Inputs Acceptable 000_ 1 CR 1 004 Response Unacceptable Error Code CR 9 6 11 CR_NMSLOT1 Command Command CR_NMSLOT1 CR Details Get a card name inserted to Input 1 Acceptabl...

Page 43: ...1 The same data as CF_NMSLOT1 Response Unacceptable Error Code CR 9 6 15 CR_IDSLOT1 Command Command CR_IDSLOT1 CR Details Get ID information of Input 1 This command is used to recognize the inserted board and specify the valid input source Acceptable 000_ 1 CR 1 00 Video board Valid Input Source VIDEO YC S VIDEO 03 Network board Valid Input Source None BLANK 04 Component board Valid Input Source A...

Page 44: ...de CR 9 6 17 CR_IDSLOT3 Command Command CR_IDSLOT3 CR Details Get ID information of Input 3 This command is used to recognize the inserted board and specify the valid input source Acceptable 000_ 1 CR 1 THE SAME AS CR_IDSLOT1 Response Unacceptable Error Code CR 9 6 18 CR_IDSLOT4 Command Command CR_IDSLOT4 CR Details Get ID information of Input 4 This command is used to recognize the inserted board...

Page 45: ... CR Details Get setting status of V Scale Acceptable 000_ 1 CR 1 32 032 Response Unacceptable Error Code CR 9 7 3 CR_VPOS Command Command CR_VPOS CR Details Get setting status of V Position Acceptable 000_ 1 CR 1 15 015 Response Unacceptable Error Code CR 9 7 4 CR_HSCALE Command Command CR_HSCALE CR Details Get setting status of H Scale Acceptable 000_ 1 CR 1 32 032 Response Unacceptable Error Cod...

Page 46: ...d lamp 1 4 has not reached replacement time while lamp 2 3 are required to replace Response Unacceptable Error Code CR 9 8 2 CR_LAMPMODE Command Command CR_LAMPMODE CR Details Get setting status of Lamp mode Acceptable 000_ 1 CR 1 FULL 4 lamp mode is selected HALF 2 lamp mode is selected Response Unacceptable Error Code CR 9 8 3 CR_AUTOLAMPCONTRL Command Command CR_AUTOLAMPCONTRL CR Details Get La...

Page 47: ...nd Lamp 3 is failed Response Unacceptable Error Code CR 9 8 5 CR_INFLAMP Command Command CR_INFLAMP CR Details Get Lamp mode switching status Acceptable 000_ 1 CR 1 NML Normal not in the lamp switching process CNG preparing for switching lamps Response Unacceptable Error Code CR 9 8 6 CR_PROJH Command Command CR_PROJH CR Details Get total running time of Projector by hour h Acceptable 000 1 CR 1 0...

Page 48: ...ISP CR Details Get setting status of Display Acceptable 000_ 1 CR 1 ON Display is set to ON OFF Display is set to OFF Response Unacceptable Error Code CR 9 9 3 CR_LOGO Command Command CR_LOGO CR Details Get setting status of Logo Acceptable 000_ 1 CR 1 ON Logo is set to ON OFF Logo is set to OFF Response Unacceptable Error Code CR 9 9 4 CR_RCODE Command Command CR_RCODE CR Details Get currently se...

Page 49: ...le Error Code CR 9 9 6 CR_ON STA Command Command CR_ON STA CR Details Get setting status of Power ON Acceptable 000_ 1 CR 1 ON Power ON Start is set to ON OFF Power ON Start is set to OFF Response Unacceptable Error Code CR 9 9 7 CR_P MANE Command Command CR_P MANE CR Details Get setting status of Power management Acceptable 000_ 1 CR 1 OFF Power management is set to OFF READY Power management is ...

Page 50: ... Acceptable 000_ 1 CR 1 MAX Fan Control Speed is set to Max NOR Fan Control Speed is set to Normal Response Unacceptable Error Code CR 9 9 10 CR_KEYDIS Command Command CR_KEYDIS CR Details Get limitation status of RC KEY use valid or invalid Acceptable 000_ 1 CR 1 NONE Both RC KEY are valid RC RC is invalid KEY KEY is invalid Response Unacceptable Error Code CR ...

Page 51: ... Unacceptable Error Code CR 9 10 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get status if there is any signal or not Acceptable 000_ 1 CR 1 ON There is signal OFF There is no signal Response Unacceptable Error Code CR 9 10 3 CR_VMUTE Command Command CR_VMUTE CR Details Get setting status of No Show Acceptable 000_ 1 CR 1 ON No Show is set to ON OFF No Show is set to OFF Response Unacceptable...

Page 52: ... as a 12 digit string 47 32 Bits 16Bits indicates the status of Main Unit No 1 16 31 24 Bits 8Bits indicates the status of Sub Power Unit No 1 8 23 16 Bits 8Bits indicates the Current sensor status 15 0 Bits 16Bits indicates the Fan sensor status e g 000000000000 power is failed at all checkpoints 000100000000 Main Unit No 1 is normal others are failed 000200000000 Main Unit No 2 is normal others ...

Page 53: ... Error Code CR 9 10 7 CR_TEMPFAIL Command Command CR_TEMPFAIL CR Details Get the temperature inside a projector when abnormal temperature status occurs It is possible to get the temperatures for more than one sensors all at once if it is applicable Acceptable 000_ 1 CR 1 e g _31 5F CR _ indicates a space When the temperature goes under 0 the first character is like 05 5F CR With more than one temp...

Page 54: ...s decoding The address such as A001 is prefixed to the Basic Serial Command or Expand Serial Command already mentioned e g Functional Execution Command A001C05 CR e g Status Read Command A001CR0 CR Projector has the function to set up its own address in Service mode Initial setting value is No 001 Available range of the value is 001 to 999 It clears the received buffer in the following cases When ...

Page 55: ...en receiving Functional Execution Command 0x06 0x0D CR When the received data cannot be decoded However when the address is FFF it executes the function but does not return the response 10 2 2 When the command pipelining is needed When it needs command pipelining the operation is the same as the remote control as below 1 Sending system issues command every 100ms 2 When receiving the applicable com...

Page 56: ...nd CR or A Address CR_ Command CR Address 3 digit number 001 999 Command string Refer to Basic and Expand Serial Command 2 The only projector with appropriate address decodes the received commands and returns the character line as the required data Required Data CR Required Data string Refer to Basic Status Read Command 3 When the received data cannot be decoded it returns CR ...