-20-
WARNING:
- For continued safety, replace with a lamp assembly of the
same type.
- Allow the projector to cool for at least 45 minutes before you
open the lamp cover. The inside of the projector can become
very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord. Allow the projector to
cool for at least 45 minutes.
2
Remove a screw with a screwdriver and remove the lamp cover.
3
Remove 2 screws and pull out the lamp assembly by grasping the han-
dle.
4
Replace the lamp assembly securely and tighten 3 screws.
5
Place the lamp cover and tighten a screw.
6
Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the interlock switch is also released to
switch off the mains power for safety.
7
Reset the Lamp Replace Counter, see below explanation
.
■
Lamp Replacement
1
Turn the projector on, and press the
MENU
button
and the on-screen menu will appear. Press the
POINT
LEFT/RIGHT
buttons to move a red frame pointer to
SETTING menu icon.
2
Press the
POINT DOWN
button to move a red frame
pointer to “Lamp counter reset” and then press the
SELECT
button. The message “Lamp replace counter
reset?” is displayed. Move the pointer to [Yes] and the
press the
SELECT
button.
3
Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
Lamp cover
Lamp Assembly
Handle
ORDER REPLACEMENT LAMP
Type No.
Service Parts No. Model
POA-LMP63
610 304 5214
PLC-XU45
POA-LMP56
610 305 8801
PLC-XU46
How to reset Lamp Replace Counter
The LAMP REPLACEMENT indicator will illuminate
when the Lamp Replace Counter reaches 1500
hours. This is to indicate that lamp replacement is
required.
You can check the lamp replace counter following to
below procedure.
1
Press and hold the pointer
UP
on the projector for
more than 20 seconds.
2
The Lamp replace Counter is displayed on upper
left corner of the screen briefly.
Normal 123 h
Eco 50
h
Total
173 h
Lamp replace counter data
How to check Lamp Replace Counter
Summary of Contents for PLC-XU45
Page 48: ... 48 CXA2101AQ RGB Matrix IC4101 IC Block Diagrams BA7078AF Selector IC6241 ...
Page 49: ... 49 CXD2064Q Digital Comb Filter IC2101 L3E01031 Level Shift IC3531 IC3561 IC Block Diagrams ...
Page 51: ... 51 ML60851 USB I F IC9801 M62393 D A IC2571 IC Block Diagrams ...
Page 52: ... 52 TA1318N AFC Detector IC6171 TB1274AF Video Decoder IC1101 IC Block Diagrams ...
Page 54: ... 54 ...
Page 82: ...ME3 XU4500 MF3 XU4600 82 47 44 44 47 44 44 Mechanical Parts List 47 57 56 47 47 Optical Parts ...
Page 83: ...ME3 XU4500 MF3 XU4600 83 44 44 54 67 Red 68 Green 69 Blue 45 45 45 Mechanical Parts List ...
Page 86: ...ME3 XU4500 MF3 XU4600 86 Mechanical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Page 88: ... ME3A Mar 2003 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 98: ...A10 PCB_ME3A ...
Page 113: ...1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L A18 15 Schematic Diagrams PLC XU45 46 Page A18 Left ...