The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side of
the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is iden-
tified with the line (
) in the schematic diagram. For continued product safety and protection of personnel
injury, servicing should be made with qualified personnel.
The following precautions must be observed.
SAFETY PRECAUTIONS
1: An isolation transformer should be connected in the
power line between the projector and the AC line
before any service is performed on the projector.
2: Comply with all caution and safety-related notes pro-
vided on the cabinet back, cabinet bottom, inside the
cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always be
certain that all the protective devices are installed
properly, such as, control knobs, adjustment covers
or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND
PROPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray
parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe to
operate without danger of electric shock.
SERVICE PERSONNEL WARNING
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always turn
off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages(15kV - 25kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
PRODUCT SAFETY NOTICE
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
!
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there parts
must be made by exactly the same parts.
DO NOT ATTEMPT TO SERVICING THE
REMOTE CONTROL UNIT.
Laser Beam may be leaked out when in disassemble
the Unit. As the Laser Beam used in this Remote con-
trol unit is harmful to the eyes.
LASER RADIATION
DO NOT STARE INTO BEAM
MAX. OUTPUT: 1mW
WAVE LENGTH: 650
±
20nm
CLASS
II
LASER PRODUCT
This product is complied with 21 CFR
part 1040.10
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
LASER-STRAHLING
NICHT IN DEN STRAHL BLICKEN
LASER KLASSE 2
IEC60825-1, Am. 1 1997
MAX OUTPUT (
) : 1 mW
WAVE LENGTH (
) : 650
±
20nm
Summary of Contents for PLC-XU40
Page 50: ... 50 IC Block Diagrams AD8075 Selector IC201 AD8183ARU Selector IC1201 AN7513 Audio Amp IC5001 ...
Page 51: ... 51 AN5870SB RGB SW IC5201 IC Block Diagrams AD9884AKS A D IC8201 ...
Page 54: ... 54 IC Block Diagrams CXD3526GG LCD Driver Timing Generator IC401 FA5502 P F Control IC611 ...
Page 55: ... 55 LA7217 Sync Separator IC5361 M62392 D A IC3561 IC Block Diagrams ...
Page 56: ... 56 NJM2284M Switch IC2101 IC Block Diagrams M62393 D A IC281 IC7801 ...
Page 82: ...MA3 XU4000 Electrical Parts List 82 Key No Part No Description Key No Part No Description ...
Page 84: ...MA3 XU4000 84 47 44 44 47 44 44 Mechanical Parts List 47 57 56 47 47 Optical Parts ...
Page 85: ...MA3 XU4000 85 44 44 54 67 Red 68 Green 69 Blue 45 45 45 Mechanical Parts List ...
Page 87: ...MA3 XU4000 87 52 a 52 46 46 46 46 52 Mechanical Parts List ...
Page 88: ...MA3 XU4000 88 Mechanical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62 ...
Page 90: ... MA3A Jan 2003 BB 400 Printed in Japan SANYO Electric Co Ltd ...
Page 107: ...1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L A10 15 Schematic Diagrams PLC XU40 A10 Left ...
Page 115: ...Diagrams Drawings MA3 XU4000 ...