PLC-XU305A/355A Expand Serial Command Functional Specifications
24/68
8.6 Input Control Command
8.6.1
CF_INPUT Command
Command “CF_INPUT_%1”[CR]
%1
“CONPUTER1” ----- Select Computer1 Input
“COMPUTER2” ----- Select Computer2 Input
“VIDEO” --------------- Select Video Input
“S-VIDEO” ------------ Select S-video
“NETWORK” -------- Select Network
“UP” ------------------- Switch Input setting forward
Computer1
→
Computer2
→
Video
→
S-video
→
Network
→
…
“DN” -------------------Switch Input setting backward
Network
→
S-video
→
Video
→
Computer2
→
Computer1
→
….
Details
Select Input
The same operation as “INPUT” button of the projector and Remote Control.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.6.2
CF_SOURCE Command
Command “CF_SOURCE_%1”[CR]
%1
Input is
Computer 1
“ANALOG” --------- Select Analog Input
“YPBPR” ----------- Select Component Input
“SCART” ----------- Select Scart Input
”UP” ---------------- Switch Input as follows
Analog
→
YPBPR
→
Scart
→
…
”DN” ---------------- Switch Input as follows
Scart
→
YPBPR
→
Analog
→
…
Input is
Computer 2
“DIGITAL” ---------- Select DVI Input
“HDCP” ------------ Select DVI HDCP Input
“ANALOG” --------- Select Analog Input
”UP” ---------------- Switch Input as follows
DIGITAL
→
HDCP
→
ANALOG
→
DIGITAL ...
”DN” ---------------- Switch Input as follows
ANALOG
→
HDCP
→
DIGITAL
→
ANALOG
→
...
Input is Video
“VIDEO” ------------- Select Composite Video Input
”UP”
”DN”
Although there is no option of source, projector accepts
parameter ”UP” ”DN”
Input is
S-video
“S
−
VIDEO” -------- Select S-Video Input
”UP”
”DN”
Although there is no option of source, projector accepts
parameter ”UP” ”DN”
Input is
Wireless
Network ------------- Select Network
”UP”
”DN”
Although there is no option of source, projector accepts
parameter ”UP” ”DN”
Details
Select Source of currently selected Input
When Input specified by %1 is inappropriate for selected Input, the projector
returns “101” and the command is not executed.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]