Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
6 Eco Fan3 Min
Fan voltage value at Eco (unit: 0.1V)
53
53
58
58
0-55
7 Eco Fan3 Max
53
53
63
63
0-55
8 Eco Fan4 Min
9999
9999
-
9 Eco Fan4 Max
9999
9999
-
Group
255
Fan Start/cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70
0-55
1 Fan Initial Volt
70
0-55
Fan3 Initial Volt
70
0-55
3 Not used
9999
-
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
130
0-55
5 Fan Cooling Speed
130
0-55
6 Fan3
Cooling Speed
130
0-55
7 Not used
9999
-
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
1-15
9 Cooling Time L
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
3
1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3
1-15
11 OnStart Cooling Start
Threshold
38
0-100
1 After shutdown cooling
Cooling after shutdown (0: No, 1: Yes)
1
0-1
Group
256
Fan lamp Voltage down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
-
0-55
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage
Down ( V×10)
30-90
Fan1 Speed Gain
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
0-55
3 Fan Speed Gain
0-55
4 Fan3 Speed Gain
0-55
5 Not used
9999
0-55
Group
257
Fan dimmer Setting
0 Dimmer Average Check
Period
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, :6sec,
90sec...10:300sec)
1
0-10
1 Dimmer Average
Dimmer Avarage Value (Read only)
-
Last Voltage Difference
-
3 Voltate Difference Goal
Group
258
Fan Ic temp for Netowrk model
0 Standby Cooling Check
Cycle
Temp A check cycle at Standby
5
1 Standby
Cooling
Start
Threshold
Cooling start threshold temp A
46
Standby Cooling Enable
Cooling in standby Enable
1
Group
260
Auto calibration (commn) * Auto calibration
0 Execute Calibration
0
0 - 1
Executes Auto-Calibration when
changiing the Value (PC White
100%)
1 Loop Count
Maximum Execution Times
(OFFSET->GAIN)
10
1 - 30
Auto Status
Result of Auto-Calibration (Last
Memory)
0
0 / 1 / 9
0: OK, 1: Adjusting,9: Error *
ReadOnly
3 AutoWait
Wait Value for each setting
1
1 - 0
4 CHECK -Tolelance
Torelance of OFFSET
1 - 55
Group
261
Auto calibration (rGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975
0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500
0 - 1000
GAIN AREA H START
White Level Acquiring Area H-Start
Position
5
0 - 1000
Summary of Contents for PLC-XU106
Page 62: ... 62 IC Block Diagrams FA5550NG P F Control IC621 LC87F2G08A5AN6 UART IC9885 ...
Page 63: ... 63 IC Block Diagrams MAX232ECPWRP RS 232C Driver IC3801 MR4010 Power OSC IC631 ...
Page 65: ... 65 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 PW190 Scaler IC301 ...
Page 94: ... KB8AC October 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...